34
3.9. Fuse locations.
In order to prevent electric shock and short circuit hazards, be sure to turn power off
before performing work.
Be careful not to damage the wires. Damaged wires may cause electric shock or
short circuit or present a fire risk.
Do not expose the Game BD, etc. without a good reason. Failure to observe this can
cause electric shock hazard or malfunctioning.
Do not use this product with connectors other than those that were connected and
used with the Game Board at the time of shipping. Do not carelessly connect wires to
connectors that were not used at the time of shipping, as this may cause
overheating, smoke or fire damage.
When replacing or repairing the game board and then returning it to the cabinet, be
sure to reconnect all the connectors correctly. Improper connection may cause
electric shock, short circuit or fire.
When connecting the connectors, be sure to attach them correctly.
There is only one correct way in which they must be connected.
Attempting to connect them incorrectly may cause damage to the pins on the
connectors, and cause electric shock, short circuit or fire.
In this product, setting changes are made during the Test Mode. The Game BD need
not be operated. Use the Game BD, etc. as is with the same setting made at the time
of shipment so as not to cause electric shock and malfunctioning.
Static electricity from your body may damage some electronics devices on the IC
board. Before handling the IC board, touch a grounded metallic surface so that the
static electricity can be discharged.
When exchanging the game board place and post off the damaged board in the new
board's special packaging. If you do not have the packaging or it is damaged order
one using the following product number/name <601-11691: CARTON BOX LBG>.
When sending a board for repairs or do not dismantle the board in any way prior to
sending it away. It may not be possible to meet your request if any parts are missing.
Send a game board in for repair with the key chip still inserted.
There are a number of fuses used on this machine to protect the user and the machine from damage. Only
replace the fuse once you have remove the cause of its failure. Detailed below is a list of the fuses used,
their location and if relevant P.C.B. reference:
PART NUMBER
LOCATION
TYPE & DETAILS
QTY
514-5078-2000 WH
HDF
(60033UK)
2A T CERAMIC 20X5MM
2
514-5078-2000
WH HDF 60029-02UK)
2A T CERAMIC 20X5MM
4
514-5079-10000
XFMR (560-LGBH-UK)
10A T CERAMIC 32X6.3MM
1
514-5090-3000 FL
UNIT
(390-7001-30UK)
3A T CERAMIC 25X6.3MM
1
514-5078-10000
IEC INLET (EP1387)
10A T CERAMIC 20X5MM
1
Summary of Contents for HOUSE OF THE DEAD 4 SUPER DELUXE
Page 18: ...15 Ensure adequate ventilation is maintained as detailed below...
Page 103: ...100 10 15 Display internal test pattern...
Page 105: ...102...
Page 121: ...118 3 Disconnect the two connectors 4 Remove the six screws from the side of the projector...
Page 124: ...121 9 After exchanging the LED board enter TEST Mode and perform a lighting test...
Page 145: ......
Page 146: ......
Page 147: ......