SPN CID SID PID PPID
FMI
J
ohn De
e
re
Volvo
Perkins
Description Comment
656 6 6 656
Cylinder #6 injector status
0
Injector outside the specifications
Recalibration of the injectors
required
1
Injector outside the specifications
Recalibration of the injectors
required
2
Short circuit high side to B+
3
Short circuit high side to low side or low
side to B+
4
Short circuit high or low side to ground
5
Cylinder #6 circuit open
6
Cylinder #6 circuit shorted
7
Cylinder #6 balancing error/mechanical
failure
11
Cylinder #6 unknown error/mechanical
failure
676
39
Glow
plug
relay
status
3
Glow plug relay voltage high
5
Glow plug relay voltage low
677 39 3
Start
relay
status
3
Start relay control short circuit to high
4
Start relay control short circuit low
5
Start relay control open circuit
678
41
8
Volt
power
supply
3
ACM 8 Volt DC supply open/short to B+
4
ACM 8 Volt DC supply open/short to
ground
679
42
Regulation sensor of the injection
pressure control
723
342
Secondary
speed
sensor
2
Secondary engine speed sensor data
intermittent
11
Secondary engine speed sensor loss of
signal
12
Loss of signal/sensor failure
729 70
Inlet air heater signal/Preheat
detection
3
Inlet air heater signal high
5
Inlet air heater signal low
810
Vehicle
speed
2
Calculated vehicle speed input noise
Not possible with Genset
application
861
861
Diagnostic
output
status
3
Diagnostic output open/short to B+
4
Diagnostic output short to ground
898
CAN
throttle
status
9
Speed value invalid or missing
970
6
Auxiliary engine shutdown switch
status EMS
2
Auxiliary engine shutdown switch signal
invalid
Not used
31
Auxiliary engine shutdown switch active
971
External engine de rate switch status
31
External engine de rate switch active
Not used
291/297
Summary of Contents for R570U
Page 1: ...User and maintenance manual for generating sets R570U 33504081501NE_1_1 ...
Page 15: ...Alternator Cabinet Figure 1 3 Examples of identification plates 13 297 ...
Page 18: ...Sockets voltage 208 120V 16 297 ...
Page 125: ...9 Appendix 9 1 Appendix A Engine user and maintenance manual 123 297 ...
Page 126: ...124 297 ...
Page 128: ...126 297 ...
Page 129: ...OPERATOR S MANUAL Generating set and industrial engines 16 liter EMS 2 127 297 ...
Page 159: ...157 297 ...
Page 218: ...216 297 ...
Page 220: ...218 297 ...
Page 222: ...7748681 English 12 2011 220 297 ...
Page 223: ...9 2 Appendix B Alternator user and maintenance manual 221 297 ...
Page 224: ...222 297 ...
Page 226: ...224 297 ...
Page 250: ...www leroy somer com 248 297 ...
Page 261: ...Installation and maintenance R250 A V R 4067 en 2009 05 b LEROY SOMER 11 259 297 ...
Page 281: ...2012 03 e LEROY SOMER 19 Installation and maintenance R 450 AVRs 4531 en 279 297 ...
Page 282: ...www leroy somer com 280 297 ...