4.6 - Dismantling, reassembly
(see sections 5.4.1. & 5.4.2.)
During the warranty period, this
operation should only be carried out in
an LEROY-SOMER approved workshop
or in our factory, otherwise the warranty
may be invalidated.
Whilst being handled, the machine
should remain horizontal (rotor not
locked in position). Check how much the
machine weighs (see 4.8.3) before
choosing the lifting method.
4.6.1 - Tools required
To fully dismantle the machine, we
recommend using the tools listed below:
- 1 ratchet s extension
- 1 torque wrench
- 1 set of flat spanners: 8 mm, 10 mm, 18 mm
- 1 socket set: 8, 10, 13, 16, 18, 21, 24, 30 mm
- 1 puller (U35) / (U32/350)
4.6.2 -Screw tightening torque
See section 5.4.
4.6.3 - Access to diodes
- Open the air intake grille (51).
- Disconnect the diodes.
- Check the 6 diodes using an ohmmeter or
a battery lamp (see section 4.5.2).
If the diodes are faulty,
- Remove the surge suppressor (347).
- Remove the 6 «H» nuts for mounting the
diode bridges on the support.
- Change the crescents, respecting the
polarity.
4.6.4 - Access to connections and the
regulation system
Access directly by removing the top of the
cover (48) or the AVR access door (466).
4.6.5 - Replacing the NDE bearing
- Remove the air intake grille (51).
- Remove the lid of the protective cover (48)
and the side panels (366) and (367).
- Remove the hook (21) and the cover rear
panel (365).
- Replace the hook (21) in order to manipulate
the flange.
- Disconnect the exciter wires (5+,6-).
If using a single-bearing or double-bearing
machine with the regreasable bearing
option:
- Remove the bearing thrust screws (78).
- Remove all 5 screws (37).
- Remove the shield (36).
- Take out the antifriction bearing (70) using
a puller with a central screw (see drawing
below).
- Fit the new antifriction bearing onto the
shaft after heating it by induction to
approximately 80 °C.
- Mount the new preloading (wavy) washer
(79) + the new “O” ring seal (349) in the
shield (36).
If using a single-bearing or double-bearing
machine with the regreasable bearing
option:
- Screw a threaded rod into the thrust
bearing (78).
- Refit the end shield on the machine using
a dowel and nut in the shaft extension (see
drawing).
WARNING
238/297
Summary of Contents for R570U
Page 1: ...User and maintenance manual for generating sets R570U 33504081501NE_1_1 ...
Page 15: ...Alternator Cabinet Figure 1 3 Examples of identification plates 13 297 ...
Page 18: ...Sockets voltage 208 120V 16 297 ...
Page 125: ...9 Appendix 9 1 Appendix A Engine user and maintenance manual 123 297 ...
Page 126: ...124 297 ...
Page 128: ...126 297 ...
Page 129: ...OPERATOR S MANUAL Generating set and industrial engines 16 liter EMS 2 127 297 ...
Page 159: ...157 297 ...
Page 218: ...216 297 ...
Page 220: ...218 297 ...
Page 222: ...7748681 English 12 2011 220 297 ...
Page 223: ...9 2 Appendix B Alternator user and maintenance manual 221 297 ...
Page 224: ...222 297 ...
Page 226: ...224 297 ...
Page 250: ...www leroy somer com 248 297 ...
Page 261: ...Installation and maintenance R250 A V R 4067 en 2009 05 b LEROY SOMER 11 259 297 ...
Page 281: ...2012 03 e LEROY SOMER 19 Installation and maintenance R 450 AVRs 4531 en 279 297 ...
Page 282: ...www leroy somer com 280 297 ...