SPN CID SID PID PPID
FMI
J
ohn De
e
re
Volvo
Perkins
Description Comment
1172
Input temperature of the TGV
compressor
3
Input voltage of the temperature sensor
high
Short to V+
4
Input voltage of the temperature sensor
low
Short to V-
1180
Input temperature of the TGV turbine
0
Turbine temperature extremely high
Short to V+
16
Turbine temperature moderately high
Short to V-
1184
173
Exhaust gas temperature sensor
1239
96
Status of the pressure system of the
common rail
1347
Pump
control
valve
status
Pump control valve #1
status for 6081HF070
3
Pump control valve current high
5
Pump control valve error/mismatch
7
Fuel rail pressure control error
10
Pump control valve fuel flow not detected
1348
Pump control valve #2 status
Only for 6081HF070
5
Pump control valve #2 error/mismatch
10
Pump control valve #2 fuel flow not
detected
1485
1485
5
Pump power relay status
ECU main relay of VOLVO
EMS/EDC
2
Pump power relay fault
3
ECU main relay short circuit
high
1568
Torque
curve
selection
2
Torque curve selection invalid
4
Torque curve input voltage high
9
Torque curve selection missing
SPN CID SID PID PPID
FMI
J
ohn De
e
re
Volvo
Perkins
Description Comment
1569
Fuel
supply
status
31
Fuel de rate
1639
Fan
speed
1
Fan speed zero or absent
2
Fan speed signal erratic
16
Fan speed more than 300 rpm above its
setpoint for at least 180s
18
Fan speed more than 300 rpm below its
setpoint for at least 180s
2000
ECU
status
6
Vehicle ID missing
13
Security
violation
293/297
Summary of Contents for R570U
Page 1: ...User and maintenance manual for generating sets R570U 33504081501NE_1_1 ...
Page 15: ...Alternator Cabinet Figure 1 3 Examples of identification plates 13 297 ...
Page 18: ...Sockets voltage 208 120V 16 297 ...
Page 125: ...9 Appendix 9 1 Appendix A Engine user and maintenance manual 123 297 ...
Page 126: ...124 297 ...
Page 128: ...126 297 ...
Page 129: ...OPERATOR S MANUAL Generating set and industrial engines 16 liter EMS 2 127 297 ...
Page 159: ...157 297 ...
Page 218: ...216 297 ...
Page 220: ...218 297 ...
Page 222: ...7748681 English 12 2011 220 297 ...
Page 223: ...9 2 Appendix B Alternator user and maintenance manual 221 297 ...
Page 224: ...222 297 ...
Page 226: ...224 297 ...
Page 250: ...www leroy somer com 248 297 ...
Page 261: ...Installation and maintenance R250 A V R 4067 en 2009 05 b LEROY SOMER 11 259 297 ...
Page 281: ...2012 03 e LEROY SOMER 19 Installation and maintenance R 450 AVRs 4531 en 279 297 ...
Page 282: ...www leroy somer com 280 297 ...