1-8
Introduction and Specifications
Date Code 20010731
SEL-352-1, -2 Instruction Manual
Output Contacts:
Standard:
Make: 30 A; Carry: 6 A continuous carry at 70°C, 4 A continuous carry at 85°C;
1 second rating: 50 A; MOV protected: 270 Vac, 360 Vdc, 40 J;
Pickup time: Less than 5 ms; Dropout time: Less than 5 ms, typical.
Breaking Capacity (10000 operations):
24 V
0.75 A
L/R = 40 ms
48 V
0.50 A
L/R = 40 ms
125 V
0.30 A
L/R = 40 ms
250 V
0.20 A
L/R = 40 ms
Cyclic Capacity (2.5 cycles/second):
24 V
0.75 A
L/R = 40 ms
48 V
0.50 A
L/R = 40 ms
125 V
0.30 A
L/R = 40 ms
250 V
0.20 A
L/R = 40 ms
High Current Interrupting Option:
Make: 30 A; Carry: 6 A continuous carry at 70°C, 4 A continuous carry at 85°C;
1 second rating: 50 A; MOV protected: 330 Vdc, 40 J;
Pickup time: Less than 5 ms; Dropout time: Less than 8 ms, typical.
Breaking Capacity (10000 operations):
24 V
10 A
L/R = 40 ms
48 V
10 A
L/R = 40 ms
125 V
10 A
L/R = 40 ms
250 V
10 A
L/R = 20 ms
Cyclic Capacity (4 cycles in 1 second, followed by 2 minutes idle for thermal
dissipation):
24 V
10 A
L/R = 40 ms
48 V
10 A
L/R = 40 ms
125 V
10 A
L/R = 40 ms
250 V
10 A
L/R = 20 ms
Note:
Do not use high current interrupting output contacts to switch ac control signals. These
outputs are polarity dependent.
Fast High Current Interrupting Option:
Make: 30 A; Carry: 6 A continuous carry at 70°C, 4 A continuous carry at 85°C;
1 second rating: 50 A; MOV protected: 330 Vdc, 40 J;
Pickup time: Less than 200 µs; Dropout time: Less than 8 ms, typical.
Breaking Capacity (10000 operations):
24 V
10 A
L/R = 40 ms
48 V
10 A
L/R = 40 ms
125 V
10 A
L/R = 40 ms
250 V
10 A
L/R = 20 ms
Cyclic Capacity (4 cycles in 1 second, followed by 2 minutes idle for thermal
dissipation):
24 V
10 A
L/R = 40 ms
48 V
10 A
L/R = 40 ms
125 V
10 A
L/R = 40 ms
250 V
10 A
L/R = 20 ms
Note:
Fast High Current Interrupting Option output contacts
are not
polarity dependent.
Note:
Make per IEEE C37.90: 1989; Breaking and Cyclic Capacity per IEC 60255-23
[IEC 255-23]: 1994.
Optoisolated Inputs:
250 Vdc: Pickup 200 – 300 Vdc; Dropout
150 Vdc.
125 Vdc: Pickup 105 – 150 Vdc; Dropout
75 Vdc.
110 Vdc: Pickup 88 – 132 Vdc; Dropout
66 Vdc.
48
Vdc:
Pickup 38.4 –
60 Vdc; Dropout
28.8 Vdc.
24
Vdc:
Pickup 15.0 – 30
Vdc.
Note
: 24, 48, 125 Vdc optoisolated inputs draw approximately 4 mA of current, 110 Vdc inputs
draw approximately 8 mA of current, and 250 Vdc inputs draw approximately 5 mA of
current. All current ratings are at nominal input voltage.
Summary of Contents for SEL-352-1
Page 8: ......
Page 10: ......
Page 12: ......
Page 30: ......
Page 68: ......
Page 186: ......
Page 292: ......
Page 302: ......
Page 368: ......
Page 370: ......
Page 374: ......
Page 380: ......
Page 382: ......
Page 384: ......
Page 386: ......
Page 396: ......
Page 404: ......
Page 422: ......
Page 442: ......