Special programming operations on Art. 4660C, 1602, 1602VC
On Art. 4660C, 1602 and 1602VC it is possible to carry out a series
of special programming operations according to the various system
requirements.
1.
On the terminal block of articles 4660C, 1602 and 1602VC set
the switch to programming (red square) (Figure 1A).
2.
On the microswitches of the article (Figure 2), set the code for
the function to be programmed. Use the following table as a
reference.
3.
On the terminal block of articles 4660C, 1602 and 1602VC
connect terminal S with – (Figure 3).
4.
Wait for a programming confirmation tone and remove the
jumper between terminal S and -.
5.
At the end of the procedure, make sure you have set the switch
to standby (white) (Figure 2A), removed the jumpers between
terminals S and - and turned all the microswitches to OFF (0) as
shown in Figure 4.
To carry out another special programming operation, repeat the
above operations from point 1 to point 5.
Art. 3309
Fig. 1A
Fig. 2A
Fig. 1
Fig. 3
Fig. 2
Fig. 4
DIP switches ON
Configuration reference
number
10-second reset wait time (factory setting)
1,2,5,6,7,8
243
1-second reset wait time
3,5,6,7,8
244
Deactivation of door lock confirmation tone and door lock time setting 2 seconds (factory-settings)
1,3,5,6,7,8
245
Activation of door lock confirmation tone
2,3,5,6,7,8
246
Door lock time 8 seconds
1,2,3,5,6,7,8
247
Sending single call (factory setting)
4,5,6,7,8
248
Sending call repeated 3 times
1,4,5,6,7,8
249
Door lock release control normally open (NO) (factory setting)
2,4,5,6,7,8
250
Door lock release control normally closed (NC)
1,2,4,5,6,7,8
251
Door lock release active even with no call (factory setting)
3,4,5,6,7,8
252
Door lock release only enabled for the user called
1,3,4,5,6,7,8
253
Reset of all factory settings
2,3,4,5,6,7,8
254