MT SBC 01
77
MT SBC 01
Programming switching device Art. 1224A
• Each switching module is equipped
with a pair of DIP switches with
8 selectors (see figure). The two DIP
switches define the MIN and MAX
range of codes that can be recognised
by the switching device.
• Remember that the MIN and MAX DIP
switches define the lowest and highest
user codes respectively which can be
connected to the riser.
• For setting the desired values, refer
to the table on page 79.
• Distinct switching devices must
manage code ranges which are not
overlapping.
MAIN DOOR FROM N° 1
÷
20
STAIRCASE A
STAIRCASE B
5802
5702
5802
1
2
3
4
5
6
5702
1
2
3
4
5
6
1216
1214/2C
1214/2C
1214/2C
1214/2C
4888C
4888C
1224A
1224A
4834/9
1216
• Example of coding switching device Art. 1224A of staircase A minimum number 1, maximum number 10.
MAX
MIN
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
O
N
O
N