MT SBC 01
63
MT SBC 01
• MANAGEMENT OF UNANSWERED CALLS
OPERATION
DISPLAY
DESCRIPTION
Switchboard on DAY:
A
(——) 21:40
The system is in
WED 12/03/07
standby.
Switchboard on NIGHT:
A
NIGHT 21:40
WED 12/03/07
A call comes in
CALL FROM
from user 2.
USER 002
If the switchboard does not answer within 30 sec. or another call arrives from the riser.
Switchboard on DAY:
The figures in
brackets indicate the number
A
(01) 21:40
of unanswered calls
WED 12/03/07
(MAX 10). The eleventh
call replaces the first.
Switchboard on NIGHT:
A
NIGHT 21:40
flashes.
WED 12/03/07
Press
to display
CALL BACK
all the unanswered
USER 002
calls
If you want to call back user 2.
CALLED
Call
USER 002
successful.
Or
Press the key
USER 002
Call
NOT AVAILABLE
unsuccessful.
Or
USER
The system is busy.
BUSY
If you want to cancel the call from the memory.
Press CANC
NO USER
The memory is empty.
TO CALL BACK
• DOOR LOCK RELEASE
OPERATION
DISPLAY
DESCRIPTION
Starting condition:
A
(——) 21:40
standby
WED 12/03/07
Press
A
(——) 21:40
If the door lock is released
WED 12/03/07
you will hear a
confirmation signal.
If a call has arrived from an external unit.
The switchboard rings.
CALL FOR
The display shows the name
USER 002
of the person called
if the directory contains a
name with code 002.
Press
A
(——) 21:40
If the door lock is released
WED 12/03/07
you will hear a confirmation signal.
The call is cancelled.
If the switchboard is in audio communication with the external unit.
Press
If the door lock is released
IN COMMUNICATION
you will hear a
WITH EXTERNAL UNIT
confirmation signal.
The communication ends
after 10 seconds.
• VIDEO CALL MODE
You can initiate a video call to an external unit.
If video call mode is set, the monitor called by the switchboard switches on, thus
allowing, for example, viewing of the remote cameras associated with Art. 1259C.
VIDEO mode can be configured as permanent or as single call.
OPERATION
DISPLAY
DESCRIPTION
Starting condition:
A
(——) 21:40
stand-by.
WED 12/03/2007
Press A/V to
V
(——) 21:40
enable video call mode.
WED 12/03/2007
Video call mode must be set in advance as described below.
OPERATION
DISPLAY
DESCRIPTION
Starting condition:
A
(——) 21:40
stand-by.
WED 12/03/2007
Press MENU’
1-CHANGE TIME
SETTINGS
2-CHANGE DATE
Use the
keys 8-
SETTING
to select the desired menu.
VIDEO MODE
Press the key
1- PERMANENT
2- SINGLE CALL.
to select the desired option
(SET VIDEO MODE)
Press
The switchboard remains in
video mode until it is disabled
with the A/V key
to activate video mode
permanently after enabling
by means of the A/V key.
1- PERMANENT
Or
2- SINGLE CALL
Press
The switchboard goes back to
audio mode at the end
to activate video mode
of the call.
only for the first call
after enabling with the A/V key.
8
TUV
1
2
ABC
• ACTUATOR CONTROL ART. 1256
Actuators can be activated in standby mode and during conversation with an
external unit.
CAUTION: It is only possible to activate actuators on the input line to
terminals LP-LP of 1998A.
N.B.: Do not use this function if no actuator is installed as it will interrupt the
communication.
OPERATION
DISPLAY
DESCRIPTION
Starting condition:
A
(——) 21:40
stand-by.
WED 12/03/2007
Press To
activate a specific actuator
ACTUATOR
key in its code.
CODE:
If the code is not present
a generic actuator will be
activated (see page 52).
A
(——) 21:40
The actuator has been activated.
Press WED
12/03/07
Or
to confirm.
ACTUATOR
The actuator is not available.
NOT AVAILABLE
ACTIVATING AN ACTUATOR IN STANDBY/SPEECH MODE