Digital call module Art. 3340
MT SBC 01
5
MT SBC 01
Arrange the modules only as indicated in the following drawing.
1) KEY FUNCTIONS
INTRODUCTION
The Comelit digital call module Art. 3340 can be used in Simplebus type systems. It is
equipped with a name directory for storing a list of user names and an alphanumeric
keypad for calling interphone users by entering their identification code.
The main specifications are as follows:
• Memory capacity: 400 names of 18 alphanumeric characters.
• Graphic display with 128x64 dots/pitch resolution.
• 2 call management modes : Standard or indirect code.
• Entering the name list ( Download ) by means of programmer Art.1230 or by means of
connection with a PC fitted with software Art.1249/A.
• Names can be entered by means of a PC connection over an RS232 line or over an
RS485 line using interface card Art. 1319 (see system diagram CA/EN/108 on
page 119).
• Reading (Upload) of the name list stored in the directory module by means of
connection with a PC fitted with software Art.1249/A.
• Access control with the possibility of storing up to 300 password codes to activate the
relay in the porter module, typically used as a door lock release.
• Possibility of displaying the graphic interface messages in one of the 9 languages
available.
CALL – SELECT MENU
BACK:
Scrolls through the user name
list in reverse alphabetical order
FORWARD:
Scrolls through the user
name list in alphabetical order.
SEARCH FOR NAME- EXIT MENU
CALL –
LOCAL DOOR LOCK RELEASE
DELETE CHARACTER
or CALL
2) INSTALLATION OF THE MODULE
To prevent any interference caused by electrostatic discharges, it is advisable to
screen the casing as shown in diagram CA/EN/108 on page 119.
3) ACCESSING CONFIGURATION MODE
Module powered with
terminal PR connected to
the - terminal.
Or:
With the module in
standby, press
, enter
the supercode and confirm
by pressing
again.
The module is in
programming mode:
to select the menu
▲▼
to scroll through the
menu
to go back to the
previous menu.
NAME DIRECTORY
ACCESS CONTROL
SETTINGS
INITIAL CONDITION
4) SETTING THE LANGUAGE
4A) THE FIRST TIME THE MODULE IS TURNED ON, THE LANGUAGE HAS NOT YET
BEEN SELECTED:
Module powered up.
SELECT LANGUAGE:
* ITALIANO
ENGLISH
Scroll the list
by means of the
▲▼
keys.
Press
to select the
desired language.
* ITALIANO
ENGLISH
FRANCAIS
The DEFAULT option
sets ITALIAN. The next time
the module is turned on,
selection of the language is
requested again.
DISPLAY
DESCRIPTION
OPERATION
4B) CHANGING THE LANGUAGE SET PREVIOUSLY:
Configuration mode has
been accessed (see point 3).
NAME DIRECTORY
ACCESS CONTROL
SETTINGS
SELECT LANGUAGE
* ITALIANO
ENGLISH
SELECT LANGUAGE
ITALIANO
* ENGLISH
The default language on
power up is Italian.The
language set is marked by
an asterisk on the left-hand
side.
The DEFAULT option sets
ITALIAN. The next time the
module is turned on,
selection of the language is
requested again.
Select the SETTINGS
MENU /
SELECT LANGUAGE.
Scroll the list by means of
the
▲▼
keys.
Press
to select the
desired language.
DISPLAY
DESCRIPTION
OPERATION
DISPLAY
DESCRIPTION
OPERATION
TEST
DESCRIPTION
5) SELF-TESTING
On power-up, the device runs a diagnostic test of the connections to check for
correct communication with porter module Art. 1602/4660C and the keypad module
which makes up Art. 3340. If the word OK appears next to the item, then it has passed
the test, otherwise, if the word FAILED appears it has failed the test. On completion of
self-testing, press the
▼
key to put the module in standby.
The table below summarises the meaning of the individual tests:
INITIALIZATION
SERIAL PORT
MODE
Checks the EEPROM which contains the user name list.
If the test fails, the module is faulty.
If the test fails, check correct serial connection with porter
module Art.1602 / 4660C.
Check presence of the alphanumeric keypad which makes
up Art. 3340. If the number 3342 appears next to the
description, correct connection between the alphanumeric
keypad and the directory module must be checked.