MT SBC 01
13
MT SBC 01
7G) DISPLAYING THE NUMBER OF NAMES STORED IN THE DIRECTORY,
THE SOFTWARE VERSION INSTALLED AND THE ID CODE
Select the INFO menu
Configuration mode has
been accessed
(see point 3)
REV. 2.4
NAMES STORED: 00
ADDRESS RS485
NAME DIRECTORY
ACCESS CONTROL
SETTINGS
DISPLAY
DESCRIPTION
OPERATION
8) MODIFYING THE SYSTEM PARAMETERS
8A) SETTING THE PARAMETERS OF PORTER MODULE ART. 1602-4660C
(door lock release time, audio timing and reset wait time.
“Reset wait time” means the time lapse between the moment at which one call is closed
and the next can be started).
Press
to select the
SETTINGS / SYSTEM
PARAMETERS/ PORTER
PARAMETERS menu
Select the parameter to be
modified.
EXAMPLE:
AUDIO TIMING
Modify the parameter value
by means of the
▲▼
keys;
to cancel the operation
press
.
Confirm the value
by pressing
.
Configuration mode has
been accessed
(see point 3)
Module Art. 1602 / 4660C
powered up with terminal
PR connected to the
terminal -
The module is in
programming mode
ENT. AUDIO TIMING
ENT. DOOR LOCK TIME
ENT. RESET TIME
ENT. AUDIO TIMING
ENT. DOOR LOCK TIME
ENT. RESET TIME
VALUE IN SECS. 010
PARAMETER
CHANGED
Admissible values
Audio timing: from 10 to 180 sec.
door lock release time: from 1 to
99 sec.
Reset wait time: from 0 to
10 sec.
A confirmation tone will be
heard on porter module
Art. 1602/4660C
NAME DIRECTORY
ACCESS CONTROL
SETTINGS
DISPLAY
DESCRIPTION
OPERATION
8B) DISPLAYING THE PARAMETERS OF PORTER MODULE ART. 1602 – 4660C
(door lock release time, audio timing and reset wait time)
Select the SETTINGS /
SYSTEM PARAMETERS/
PORTER PARAMETERS/
VIEWING menu.
Configuration mode has
been accessed
(see point 3)
Module Art. 1602 / 4660C
powered up with terminal
PR connected to terminal -
DOOR LOCK TIME 01
AUDIO TIMING 010
RESET WAIT TIME 10
NAME DIRECTORY
ACCESS CONTROL
SETTINGS
The display shows the
parameters set on porter
module Art.1602/4660C.
CAUTION:
The function is only
guaranteed with porter
modules which have a
software version of 2.0 or later
DISPLAY
DESCRIPTION
OPERATION
8C) SETTING THE ID CODE ( Default = 0 )
The ID code is only used in special applications
Configuration mode has
been accessed
(see point 3)
Select the SETTINGS /
SYSTEM PARAMETERS /
ADDRESS RS485 menu
The ID code displayed
is not the one configured.
NAME DIRECTORY
ACCESS CONTROL
SETTINGS
ADDRESS RS485: 01
DISPLAY
DESCRIPTION
OPERATION
Press the key
to
confirm the selection
Use the
▲▼
keys to modify
the value of the ID code
Press the key
to store the value
ADDRESS RS485: 01
ADDRESS RS485: 254
PARAMETER
CHANGED
The ID code displayed is not
the one configured
The code can have a value
from 1 to 255.
9) SETTING THE TYPE OF CONNECTION WITH THE PC,
RS232 or RS485 (Default = RS232)
Configuration mode has
been accessed
(see point 3)
Select the SETTINGS /
TYPE OF DOWNLOAD
Select the download mode
using the
▲▼
keys.
EXAMPLE: RS485
Press the key
to confirm the selection
The DEFAULT setting is
RS232
The mode set
is marked
by an asterisk
on the left side
An asterisk will appear on
the left side of the item
selected.
CAUTION:
For downloading in RS485
mode, refer to wiring diagram
CA/EN/108 on page 119.
DISPLAY
DESCRIPTION
OPERATION
NAME DIRECTORY
ACCESS CONTROL
SETTINGS
TYPE OF DOWNLOAD
*RS232
RS485
TYPE OF DOWNLOAD
*RS232
RS485
TYPE OF DOWNLOAD
RS232
* RS485