MT SBC 01
23
MT SBC 01
INITIAL CONDITION
4) SETTINGS
4A) SYSTEM PARAMETERS
4A-1) CHANGING THE CONVERSATION TIME, DOOR LOCK RELEASE TIME AND
RESET WAIT TIME FOR THE PORTER MODULE
This operation enables you to change the audio timing, door lock release relay closure
time and reset wait time for the porter module.
Module Art. 3072/A
powered with terminal
PR connected to the -
terminal.
Porter module Art. 3062/3262/
3268 powered with terminal
PR connected to the - terminal.
MAIN
SETTINGS
↓
The module is in
programming mode:
to select the menu
▲▼
to scroll through the
menu
to go back to the menu
below
The porter module is in
programming mode.
It is possible to change
the audio timing, door lock
release relay activation time
and reset wait time.
Pressing the
▲
or
▼
key
continuously
increases or
reduces the value in steps of
10.
If entry is successful.
DISPLAY
DESCRIPTION
OPERATION
Using the
▲
or
▼
keys,
select the MAIN
SETTINGS/ SYSTEM PAR./
PORTER PAR. menu
Using the
▲
or
▼
keys,
scroll the menu options and
select the one for the
parameter you want to
change.
EXAMPLE:
Changing
audio timing.
Enter the desired value
using the
▲
or
▼
keys.
EXAMPLE:
100
Press
to confirm the
value of the parameter.
When you have made
the change, remove the
connections between PR
and – on the terminals of
3072/A and porter modules
3062 / 3262 / 3268.
PORTER PAR.
ENT. t AUDIO
ENT. t AUDIO
VALUE: _ _ _
ENT. t AUDIO
VALUE: 100
PARAMETER
CHANGED
↑
↓
↑
↓
INITIAL CONDITION
4A-2) DISPLAYING THE AUDIO TIMING, DOOR LOCK RELEASE TIME AND RESET
WAIT TIME FOR THE PORTER MODULE
This operation enables you to display the audio timing, door lock release relay closure
time and reset wait time for the porter module.
Module Art. 3072/A
powered with terminal PR
connected to the - terminal.
Porter module Art.
3062 / 3262 / 3268
powered with terminal PR
connected to the - terminal.
The module is in
programming mode:
to select the menu
▲▼
to scroll through the
menu
to go back to the menu
below.
The porter module is in
programming mode.
MAIN
SETTINGS
↓
AUDIO TIMING
VALUE: 100
↑
↓
DISPLAY
DESCRIPTION
OPERATION
Select the
MAIN SETTINGS /
SYSTEM PAR. /
PORTER PAR. /
VIEWING menu.
After 3 seconds
The display shows
the values
of the other parameters in
sequence.
DISPLAY
DESCRIPTION
OPERATION
When you have made the
change, remove the
connections between PR
and – on the terminals of
3072/A and porter modules
3062 / 3262 / 3268.
TYPE OF DOWNLOAD
VALUE: 0
TYPE OF DOWNLOAD
VALUE: 1
PARAMETER
CHANGED
↑
↓
↑
↓
If entry is successful.
DISPLAY
DESCRIPTION
OPERATION
Select the MAIN
SETTINGS / SYSTEM
PAR. / TYPE OF
DOWNLOAD menu.
Enter the desired value
using
▲
or
▼
keys
.
EXAMPLE:
1
Press the key
to confirm the value
of the parameter.
When the change has been
made remove the
connections between PR
and – on the terminal of
3072/A.
INITIAL CONDITION
4A-3) TYPE OF SERIAL DOWNLOAD
The parameter sets the type of connection used for downloading the user list.
Either an RS232 or RS485 interface is available.
Module Art. 3072/A
powered with terminal PR
connected to the - terminal.
The module is in
programming mode:
to select the menu
▲▼
to scroll through the
menu
to go back to the menu
below.
MAIN
SETTINGS
↓
4A-4) ADDRESS RS485
The value of this parameter is used only in special applications.
INITIAL CONDITION
Module Art. 3072/A
powered with terminal PR
connected to the - terminal.
The module is in
programming mode:
to select the menu
▲▼
to scroll through the
menu
to go back to the menu
below.
If entry is successful.
If entry does not fall within
the limits.
DISPLAY
DESCRIPTION
OPERATION
ADDRESS RS485
VALUE: _ _ _
ADDRESS RS485
VALUE: 100
PARAMETER
CHANGED
Or:
ENTRY
WRONG
↑
↓
↑
↓
Select the MAIN
SETTINGS / SYSTEM
PAR. /ADDRESS RS485
menu.
Enter the desired value
using the
▲
or
▼
keys
.
EXAMPLE:
100
Press the key
to confirm
the value of the parameter.
When the change has been
made, remove the
connections between PR
and – on the terminal of
3072/A.
MAIN
SETTINGS
↓