Section 8: Appendix
TH2 Series Operator Manual
Page 8-11
8.3 OPERATION MODE SELECTION (cont’d)
8.3.6 Journal Mode
The Journal mode is identical to Continuous mode, except that neither the gap nor the I-Mark sensor is
enabled. The Sensor Type is set to
None
or
Fix
, in
Continous
mode. This means that the media is fed long
enough for all data to be printed regardless of any gaps or I-Marks.
In the figure below, n labels are printed (where n is equal to 1 or more).
Before printing, label number 1 is in the printing start position.
When all n labels are printed, label number n+1 is in the printing start position.
The size of the labels in the figure above differs. This is to indicate that normally in Journal mode, the size
depends on the data printed.
It is possible to set a fixed label length in Journal mode. In this case, the media will be fed according to this
length.
Print head
After
printing
n labels
Before
printing
Feed
direction
2
n
3
1
n+3
n+2
n+1