Section 3: Configuration and Operation
Page 3-46
TH2 Series Operator Manual
3.7 PRINTER SETUP MENU (Cont’d)
Menu
Description
7.
If calibration is successful, the screen on the left is displayed, press
enter button to proceed.
8.
Select
Yes
to confirm calibration result and save the sensor values.
Select
No
to regret calibration result. The sensor values will not be saved.
MEDIA
menu.
Enables the selection of
1.Size
,
2.Sensor Type
,
3.Calibrate
or
4.Max feed.
Select
4.Max feed
.
MAX FEED
sets the maximum feed length to feed before generating “Gap not
found” or “I-mark not found”. Normally, the default value can be used for all
media and format sizes.
In certain applications, it is important to be notified about label detection prob-
lems as soon as possible. Then
MAX FEED
should be set to the physical label
length.
MAX FEED
must always be at least as long as the physical media length.
Displays the media
MAX FEED
range and input field with existing value and
unit.
Enables input of new media
MAX FEED
length.
Setting range is between
128
and
1880
, and the default value is
1872 dot
.
Note:
If the value is outside the allowed range,
Invalid
will be displayed.
If the value is acceptable,
Saved
will be displayed when
enter button is
pressed.