7. Troubles
●
Code :
A3-2111
A3-2112
●
Error message :
Actuator Sensor Fail
Actuator Sensor Fail
●
Symptom / Cause :
y p
Calibration for density sensor is failed
●
Troubleshooting method :
Execute the density calibration.
1. Open the door and close it.
2. Turn off the machine then on.
3. Remove the ITB and re-install it.
●
Replacement part
- JC96-05689A : CARTRIDGE-TRANSFER ITB
Service Manual
CLX-9250/9350 series
7-2
shooting
lure #A3-2111: Please open/close door.
lure #A3-2112: Please open/close door.
SAMSUNG ELECTRONICS