7. Troubles
●
Code :
C5-1531
●
Error message :
ITB Unit Failure #C5
●
Symptom / Cause :
The machine can not detect the position movement of
●
Troubleshooting method :
1. Check if the Engage Sensor is working normally.
2. If the sensor can not detect the engage operation, c
If the connection is OK, replace the sensor.
3. If the sensor has no problem, check if the DC moto
4. If there is a any motor noise, replace the DC motor A
●
Replacement part
JC95-01056A : COVER-SIDE MOTOR DC
0604-001393 : PHOTO-INTERRUPTER
Service Manual
CLX-9250/9350 series
7-5
shooting
5-1531: Turn off then on.
f the transfer roller 2 within the programmed time.
check the harness connection.
or is working normally.
Assy.
SAMSUNG ELECTRONICS