7. Troubles
●
Code :
C5-1551
●
Error message :
ITB Unit Failure #C5
●
Symptom / Cause :
The transfer roller is not installed or the High voltage c
●
Troubleshooting method :
1.
Remove and reinstall the transfer roller unit.
2.
If the problem persists, check the followings.
a. Replace the transfer roller unit.
b. Check the HVPS board and transfer harness.
c. Check if the HVPS output is normal.
●
Replacement part
JC95-01038A : COVER-SIDE TRANSFER ROLLER
Service Manual
CLX-9250/9350 series
7-5
shooting
5-1551: Turn off then on.
circuit has some problem.
SAMSUNG ELECTRONICS
56