Simulated Water Flow Mode Adjustment Increments
These settings allow the operator to set flow rate increments to be used when unit is operating in Water Simulation
Mode. Simulated water flow rate will decrease/increase by this amount when
INCREASE
or
DECREASE
buttons are
pressed (minor increment) or held down (major increment).
Menu item: SIM. WT. FLOW INC. – minor increments for simulated water flow adjustment
Menu item: SIM. WT. FLOW M. INC. – major increment for simulated water flow adjustment
1. Select USER SETTINGS on the menu screen by pressing the
INCREASE
or
DECREASE
button. Press the
SELECT
button to access this menu.
2. In USER SETTINGS, select the ‘SIM. WT. FLOW INC.’ (for minor increment setting) or ‘SIM. WT. FLOW
M. INC.’ (for major increment setting) item using the
INCREASE
or
DECREASE
button. Press the SELECT
button to change the value.
3. Entry screen will open. Value field will be selected and the current adjustment increment will be read. Use the
ON/OFF
or
SELECT
buttons respectively to decrease or increase the value until the desired new setting is
reached. Hold down either button to automatically edit the valve in greater increments.
4. To save the new value press the
INCREASE
or
DECREASE
button until the ‘SAVE AND RETURN’ item is
selected. Press the
SELECT
button to save the change, or press the
ON/OFF
button to cancel the change (initial
value will be restored).
Set Date and Time
These settings allow the operator to set the date and time for all AccuMax system components and other FRC products
that feature a built-in date/time clock. Date and time is used to time stamp events recorded in a display module log. If date/
time is not set, the log will use elapsed time since the last power-up instead.
NOTES:
• Date and Time information for the AccuMax system is kept in the Hydraulic Controller device. The
Hydraulic Controller is equipped with a battery backup to maintain the date and time when the system is powered
OFF. Make sure this device is connected to the CAN network, powered and operational before changing the
date/time.
• Date and Time needs to be set only once for the entire system. All display modules and other devices will
synchronize their internal clocks when this setting is changed, or within one minute since it has been connected
to the CAN network.
• Check if the date/time setting is correct after replacing or servicing the Hydraulic Controller.
1. Select USER SETTINGS on the menu screen by pressing the
INCREASE
or
DECREASE
button. Press the
SELECT
button to access this menu.
2. In USER SETTINGS, select the ‘SET DATE/TIME’ item using the
INCREASE
or
DECREASE
button. Press
the
SELECT
button to enter the date and time setting screen.
3. Date time screen will open. The layout of the data field on this screen will match set date and time formats. Active
data field will be highlighted in black. Use
ON/OFF
or
SELECT
buttons
respectively to decrease or increase the value of active data field. Hold
down either button to change value automatically. Press
INCREASE
or
DECREASE
buttons to the change active data field that needs to be changed.
4. When all data fields are set, press
INCREASE
or
DECREASE
button until
the ‘SAVE AND RETURN’ item is selected. Press the
SELECT
button
to set date and time for the system, or press the
ON/OFF
button to cancel
(date and time will not be changed).