RTW DigitalMonitor 8ch 10689
161
E 6 Installation E 6.4 Change of AES-3 input termination
E 6.4 Change of AES-3 input termination
Using the DIP switch on the main pcb the AES-3 input termination can be
changed:
On (1, 2, 3, 4):
110
Ω
Off:
High-Z
Factory set is 110
Ω
.
Open the unit see
Chapter E 7.3
Fig. E 6-2: Partitial view of the main pcb with the DIP switch
1
: AES-3 input 1 termination
2
: AES-3 input 2 termination
3
: AES-3 input 3 termination
4
: AES-3 input 4 termination