6-14 SERVICE CALL
CODE
CONTENTS
CAUSE
ACTION
0002
Disorder of communication with Sub CPU
This occurs when the Sub CPU is not
detected after turning on the printer
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main Board and
Servo Board.
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
0004 Sub CPU SRAM error
SRAM is broken.
Servo Board replacement
0005 An error occurs during downloading a
program for sub CPU.
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main Board and
Servo Board.
A noise on a signal.
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
0006 An error occurs when communicating with
sub CPU.
A noise on a signal while sending a command.
Sub CPU was reset to default.
Tried to communicate when Sub CPU was reset to
default.
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
0007 An error occurs while sending a command.
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main Board and
Servo Board.
A noise on a signal while sending a command.
Sub CPU was reset while sending a command.
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
0008 There is a problem with synchronizing serial
communication to Sub CPU.
Servo Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main Board and
Servo Board.
A noise on a signal.
Check cable connection between Main Board and Servo
Board.
Check the other cable connections of Servo Board.
Servo Board replacement
Main Board replacement
Flexible cable replacement
0010 Network I/F Initialize has not been completed.
Network I/F does not work correctly.
Firmware for Network I/F is not installed.
Check if the firmware is installed into Network I/F.
Main Board replacement
0101 Limit Position Initialize in the Service Mode
has not been done.
Limit Position Initialize has not been done.
Limit Position Initialize is ended before it is completed.
Complete Limit Position Initialize correctly.
0102 Limit Sensor is ON when it should be OFF, or
vice versa.
Limitr does not work correctly or is broken.
Limit Sensor replacement
Check the mechanical backlash or looseness/fixity with
the scan axis related parts.
0104 Capping unit does not work correctly.
Capping Motor does not work correctly or is broken.
Capping Unit does not work correctly or is broken.
Capping Sensor does not work correctly or is broken.
Wiring or Flexible Cable has short circuited or cut-line.
Capping Motor replacement
Capping unit replacement
Capping Sensor replacement
Flexible Cable replacement
0107 Linear Encoder Setup has not been done.
Linear Encoder Setup has not been done.
Linear Encoder Setup is ended before it is completed.
Carry out Linear Encoder Setup in service menu
0108 Wiper UP/DOWN sensor is OFF although it
should be ON. Or, vice versa.
Wiper UP/DOWN Motor is broken.
Wiper Unit is broken.
Wiper UP/DOWN Sensor is broken.
Wiring or Flexible Cable has short circuited or cut-line.
Wiper UP/DOWN Motor replacement
Wiper Unit replacement
Wiper UP/DOWN Sensor replacement
Flexible Cable replacement
0109 Wiper unit does not work correctly.
Wiper Motor error
Defect of Wiper Unit
Defect of Wiper Sensor
Cut-line or short-circuit of cable and Flexible cable
Wiper Motor Replacement
Wiper Unit Replacement
Wiper Sensor Replacement
Cable and Flexible Cable Replacement
0110 There is a problem in reading the Linear
Encoder.
Read error of Linear Encoder.
Read error of Encoder on Scan Motor side.
Belt is not fixed to Head Carriage firmly.
Confirm whether Encoder Scale is between the slit of
Encoder Module in a whole width of the printer.
Check cable connection between Linear Encoder Board
and
Head Board
Confirm connection between Belt and Carriage
Linear Encoder replacement
Scan Motor replacement
Servo Board replacement
Main Board replacement
0112 It is not possible to communicate with the
Cartridge IC driver.
Cartridge IC driver has a problem (not working).
The communication wire of Cartridge IC driver cable has
short circuited or cut-line.
Ink Cartridge IC sensor replacement
0148 There is a problem with the Thermistor on the
Cyan Head.
There is a bad connection between Cyan Head and Print
Carriage Board (CN18).
There is a bad connection between Print Carriage Board
(CN2) and Head Board (CN1).
Cyan Head is broken.
Check cable connection between Head and Print
Carriage Board (CN18).
Check cable connection between Print Carriage Board
(CN2) and Head Board (CN1).
Cyan Head replacement.
0151 Head UP/DOWN sensor is OFF although it
should be ON. Or, vice versa.
Head UP/DOWN Motor is broken.
Head UP/DOWN sensor is broken.
Wiring or Flexible Cable has short circuited or cut-line.
Servo Board is broken.
Check the cable connections of Servo Board
Check the cable connections of Junction Board
Head UP/DOWN Motor Replacement
Head UP/DOWN Sensor Replacement
Cable and Flexible Cable Replacement
Servo Board Replacement
6-8
Summary of Contents for VersaUV LEJ-640
Page 32: ...2 4 MAIN BOARD_Arrangement Diagram Soldering Side ...
Page 43: ...2 15 HEAD BOARD_Arrangement Diagram Soldering Side ...
Page 54: ...2 26 SERVO BOARD_Arrangement Diagram Soldering Side ...
Page 63: ...2 35 SUB BOARD B_ Arrangement Diagram Component Side ...
Page 70: ...2 42 2 6 INK SYSTEM BOARD INK SYSTEM_Arrangement Diagram Component Side ...
Page 282: ...4 74 9 Fix the I S Cover I S Cover Hook Screw Screw ...