4-47
The test pattern is printed.
Measure the length of the feed direction and use the
value to calculate the calibration amount with the for-
mula shown in 5 .
4
5
6
Calculate the amount to be calibrated with the formula
shown in the fi gure.
CA = Calibration Amount
CL = Commanded Length (=400mm)
ML = Measured Length
Select [SETTING] under the [CALIB.DEFAULT] menu
and enter the calibration value with the Up and Down
keys.
Press the [ENTER] key to save the setting.
Parameters can be entered with an incre-
ment of 0.01%.
(MAX. +2.00% to MIN. -2.00%)
FORMULA
CA = CL - ML
ML
x 100
The test pattern is always printed with off-
set 0.00%. Even if a correction is made in
the [SETTING] menu, the test pattern is not
changed.
Scan
F
eed
500mm
400mm
SERVICE MENU
PRINT MENU
PRINT MENU
CALIB.DEFAULT
[ ]
[ ]
[ ]
[ ]
[ ]
CALIB.DEFAULT
SETTING
SETTING
+0.00% +0.15%
[ ]
Select [TEST PRINT] under [CALIB.DEFAULT] menu
and press the [ENTER] key.
3
The test print requires 510mm or more of the
media Setup width.
[ ]
SERVICE MENU
PRINT MENU
PRINT MENU
CALIB.DEFAULT
CALIB.DEFAULT
TEST PRINT
[ ]
[ ]
[ ]
[ ]
Summary of Contents for VersaUV LEJ-640
Page 32: ...2 4 MAIN BOARD_Arrangement Diagram Soldering Side ...
Page 43: ...2 15 HEAD BOARD_Arrangement Diagram Soldering Side ...
Page 54: ...2 26 SERVO BOARD_Arrangement Diagram Soldering Side ...
Page 63: ...2 35 SUB BOARD B_ Arrangement Diagram Component Side ...
Page 70: ...2 42 2 6 INK SYSTEM BOARD INK SYSTEM_Arrangement Diagram Component Side ...
Page 282: ...4 74 9 Fix the I S Cover I S Cover Hook Screw Screw ...
Page 306: ...7 2 Unpacking ...