4-79
Check the clearance between Media Thickness checking
Sensor and Bed is from 1.8mm to 2.1mm by using the
Thickness Gauge as shown in the below.
13
Confi rm that the 1.8mm gauge go through the
sensor.
Confi rm that the 2.1mm gauge hit the sensor.
From 1.8mm to 2.1mm
14
I/S MENU
I/S CONTROL
I/S CONTROL
HEAD UP/DOWN
[ ]
SERVICE MENU
I/S MENU
[ ]
[ ]
HEAD UP/DOWN
MIDDLE
[ ]
Select [I/S MENU] > [I/S CONTROL] > [HEAD UP/
DOWN] > [MIDDLE], and press the [ENTER] key to set
the head height to [MIDDLE].
Turn off the sub power SW and main power SW.
< Rear side >
Main Power SW
Sub Power SW