START-S12-M
Technical manual
-15-
3.12 Connection of the photo-beam (activated when closing) with TEST
The TEST of the photo-beam works only if the
photo-beams are installed properly. The control
unit will check all connections before opening!
In case the photo-beam are not working pro-
perlym the control unit will lit on for 5 seconds
and the gate is not moving.
To activate the
TEST
set
1
in the
PhOTO-A:
If you go back to function without TEST, do the
connection as in Par.
3.08
and put in
0
the
S06
and
S09
(deactivate if are inputs are not in test)
S 09
TEST IN PhOTO OUTPUT
1 - Activated
0 - Deactivated
S 06
TEST IN ThE INPUT
SAfETIES
1 - Activated
0 - Deactivated
3.13 Deactivation of the PHOTOCELL A when the gate is closing
S 03
Photocell A deactivated
1 - Activated
0 - Deactivated
If you set S03 it deactivates the PhOTO A after in-
tervention of slow down lS. If
S03 is 1
the time of
function
T11
is not considered
12 13 14 15 16 17 18 19 20 21 22 23
8 9 10 11
RX
TX
NC Contact
12 Vac
The contact of the receiver should be:
- Isolated
(isolated from tensions)
- Normally closed
3.11
Connection of the PHOTO-BEAMS (only when closing)
If the input PHOTO
is not used, set S16 in 0
!
12 13 14 15 16 17 18 19 20 21 22 23
8 9 10 11
RX
TX
NC Contact
12 Vac
Summary of Contents for START-S12-M
Page 30: ...START S12 Manuale tecnico 30 10 Note ...
Page 63: ...START S12 M Technical manual 30 10 Note ...
Page 95: ...START S12 Technical manual 30 10 Note ...
Page 128: ...START S12 Instrución 31 10 Note ...
Page 129: ...START S12 Instrución 32 ...
Page 130: ...START S12 Instrución 33 ...
Page 164: ...START S12 Notice d emploi 31 10 Note ...
Page 165: ...START S12 Notice d emploi 32 ...
Page 166: ...START S12 Notice d emploi 33 ...