START-S12-M
Technical manual
-20-
5.3
Set SPEED and ACCELERATION
Set up
Description
Values Accepted Standard
L 01
Minimum speed OPENING
from 1 to 200
30
L 02
Minimum speed CLOSING
from 1 to 200
20
L 03
Maximum Speed OPENING
from 1 to 200
80
L 04
Maximum speed CLOSING
from 1 to 200
40
L 05
OPENING acceleration
from 1 to 99
8
L 06
CLOSING acceleration
from 1 to 99
8
L 07
OPENING deceleration
from 0 to 25
8
L 08
CLOSING deceleration
from 0 to 25
8
L 09
Motor absorption in case of STOP
Ampere
5,0
L 10
Motor absorption in case of problems
Ampere
7,0
L 11
Power in the BRAKE OUTPUT
from 1 to 70
50
Are now given the parameters that allow you to set SPEED, ACCElERATION and ABSORPTION:
Summary of Contents for START-S12-M
Page 30: ...START S12 Manuale tecnico 30 10 Note ...
Page 63: ...START S12 M Technical manual 30 10 Note ...
Page 95: ...START S12 Technical manual 30 10 Note ...
Page 128: ...START S12 Instrución 31 10 Note ...
Page 129: ...START S12 Instrución 32 ...
Page 130: ...START S12 Instrución 33 ...
Page 164: ...START S12 Notice d emploi 31 10 Note ...
Page 165: ...START S12 Notice d emploi 32 ...
Page 166: ...START S12 Notice d emploi 33 ...