± 2g / 4g / 8g / 16g Tri-axis Digital
Accelerometer Technical
Reference Manual
PART NUMBER:
KX132-1211
Rev. 1.0
31-Jul-2019
36 Thornwood Dr.
–
Ithaca, NY 14850
© 2019 Kionix
–
All Rights Reserved
tel: 607-257-1080 – fax:607-257-1146
893-12874-1907311402-0.17
www.kionix.com -
Page
71
of
73
In FIFO, Stream, or Trigger mode, reading one sample from the buffer will remove the oldest sample and effectively
shift the entire buffer contents up, as seen in Figure 30.
Index
Sample
0
Data1
← FIFO read pointer
1
Data2
2
Data3
3
Data4
4
Data5
5
Data6
6
Data7
7
Data8
← Sample Threshold
8
Data9
buffer write pointer →
9
Figure 30:
FIFO Read from Full Buffer