![Rohde & Schwarz FSH4 Operating Manual Download Page 95](http://html.mh-extra.com/html/rohde-and-schwarz/fsh4/fsh4_operating-manual_1477834095.webp)
R&S FSH
Spectrum Analyzer Mode
Performing Spectrum Measurements
Operating Manual 1309.6275.12 - 14
76
You can transfer transducer factors to the R&S FSH with the R&S FSH4View software
package. In order to activate the measurement with the isotropic antenna, you have to
select a transducer factor file with the extension *.isotrd. For more information see
"
Test setup
The test setup for cable measurements consists of the R&S FSH and the isotropic
antenna R&S TS-EMF. All necessary cables are already connected to the antenna.
M
Connect the RF cable with the N coaxial connector to the RF input (port 1).
M
Connect the control cable (for switching between the x-, y- and z-axis) 9-pin D-Sub
connector to the power sensor interface using the adapter cable that comes with
the antenna.
M
Press the MEAS key.
M
Press the "Meas Mode" softkey.
M
Select the "Isotropic Antenna" menu item.
The R&S FSH includes the antenna in all relevant measurements.
Before displaying final measurement results, the R&S FSH performs a
measurement for each of the three antenna axis. The update rate of the trace
decreases accordingly.
Automatic antenna detection
If you connect an isotropic antenna made by Rohde & Schwarz, the R&S FSH
automatically detects and includes the antenna in measurements.
Using transducer factors
If you are using an isotropic antenna, you can select a transducer factor.
M
Press the AMPT key.
M
Press the "Transducer" softkey
The R&S FSH opens a dialog box to select the transducer factor.
M
Select the "Primary Transducer" menu item.
Transducer files
Transducer files for isotropic antennas have the extension *.isotrd. When you select a
transducer factor with that file extension, the R&S FSH will automatically activate the
isotropic antenna measurement.
M
Select the transducer factor you need with the extension *.isotrd.
M
Confirm the selection with the "Select" softkey.