![Rohde & Schwarz FSH4 Operating Manual Download Page 223](http://html.mh-extra.com/html/rohde-and-schwarz/fsh4/fsh4_operating-manual_1477834223.webp)
R&S FSH
Digital Modulation Analyzer
Measurements on LTE Signals
Operating Manual 1309.6275.12 - 14
204
Carrier Freq Error
Shows the frequency error in relation to the current center frequency of the R&S FSH.
For more information see "
Selecting the Unit of the Carrier Frequency Error
" on page
Concerning uncertainty of the reference frequency of the GPS receiver, refer to the
data sheet.
Sync Signal Power
Shows the power of the synchronization signal.
For more information see "
Selecting the Synchronization Signal
OSTP
Shows the OSTP of the signal.
Cell Identity [Grp/ID]
Shows the cell identity, cell group and cell ID the current results correspond to.
For more information see "
Cyclic Prefix
Shows the cyclic prefix the current results correspond to.
For more information see "
Traffic Activity
Percentage of traffic slots with data.
I/Q Offset
Shows the power at spectral line 0 normalized to the total transmitted power.
The I/Q offset may be an indicator for a baseband DC offset or for carrier leakage.
7.5.1.3 Allocation Summary
The allocation summary becomes active when you have set the MIMO settings to a
specific antenna connected by cable. The allocation summary contains the results for
specific aspects of the signal like channels and modulation.
For each value, the R&S FSH shows the power in dBm and the average error vector
magnitude (EVM). For more information see "
All results in the allocation summary are normalized to one resource element or one
subcarrier, respectively.