![Rohde & Schwarz FSH4 Operating Manual Download Page 202](http://html.mh-extra.com/html/rohde-and-schwarz/fsh4/fsh4_operating-manual_1477834202.webp)
R&S FSH
Digital Modulation Analyzer
Measurements on 3GPP FDD Signals
Operating Manual 1309.6275.12 - 14
183
1
Current type of result display
2
Currently selected standard
3
Header table
4
Synchronization state and GPS information
- green font: synchronization OK
- red font: synchronization failed
5
Global results
6
Channel table
7
WCDMA softkey menu
7.2.3.1 Header Table
The header table contains various settings already discussed in the sections above.
For more information see "
General Settings of the Digital Modulation Analyzer
" on
page 171 and "
7.2.3.2 Global Results
The global results include information about the complete signal.
Channel Power
Shows the power of the complete signal.
Active Channels
Shows the number of the currently measured channels.
7.2.3.3 Channel Table
The channel table is made up out of seven columns that show various information
about each channel. The number of rows depends on the number of channels that are
currently active. If a channel occupies more than one code, the results correspond to
all codes in the channel.
Channel Type
Type of code channel.
All code channels that the R&S FSH is able to recognize are shown with the correct
channel type and spreading factor.
Channels with the label CHAN are active code channels whose type could not be
detected. Codes that are inactive are not shown.
Chan#.SF
Code channel number including the spreading factor (in the form <Channel>.<SF>).
Symb. Rate (ksps)
Symbol rate that the code channel is transmitted with (7.5 ksps to 960 ksps).