Remote Control - SCPI
R&S
®
QAR
93
User Manual 1178.7200.02 ─ 09
We recommend to define a timeout of at least 10 seconds to allow for the measure-
ment to finish.
Example:
//Normalize transmission measurement
MEAS:TRAN:NORM:STAR
Usage:
Event
MEASurement:TRANsmission:VMOD
<State>
This command turns the verification mode for a transmission loss measurement on and
off.
Setting parameters:
<State>
ON | OFF | 1 | 0
*RST:
OFF
Example:
//Turn on verification mode
MEAS:TRAN:VMOD ON
6.2.4.3
Measurements (Single Cluster)
Remote commands described elsewhere:
●
●
●
●
MEASurement:REFLection:NORMalize:STARt
●
MEASurement:REFLection:NORMalize:REQuired?
MEASurement:REFLection:SCSTatistics<n>:MEAN?
...........................................................93
MEASurement:REFLection:SCSTatistics<n>:STD?
..............................................................94
MEASurement:REFLection:SCSTatistics<n>:UNIT?
............................................................ 94
MEASurement:REFLection:SCSTatistics<n>:MEAN?
This command queries the mean reflection.
Prerequisites for this command
●
Select single cluster measurement.
●
Reflection measurement results must be available.
Suffix:
<n>
.
1: Result in dB
2: Result in %
3: Linear result
You can query the unit of a result with
REFLection:SCSTatistics<n>:UNIT?
Return values:
<Reflection>
The unit is either dB or PCT.
Remote Commands