Radar Positioning Measurements
The typical procedure when measuring a radar position is as follows:
1. Start the R&S
QAR to start the system and the software.
For more information about the functionality of the software, see
2. Park the car in front of R&S
QAR.
3. Measure the DUT.
4. Save measurement data.
"Managing measurement results"
5.4.1
Test Setup
For radar positioning measurements, the test setup consists of the R&S
QAR and the
DUT, for example a radar module installed behind the bumper of a car. To measure the
position of the radar module, you simply park the car in front of the R&S
QAR. Make
sure to park the car at the correct position as indicated in
surement results.
Figure 5-20: Test setup for radar positioning measurements (side view)
The optimal distance to the front of the car depends on the location of the radar mod-
ule relative to the radome's location on the car.
●
The distance between R&S
QAR and radar module is between 60
cm and 80
cm.
●
The distance from floor to radar module is between 34
cm and 68
cm.
●
The offset of the radar module relative to the center of the R&S
QAR panel is
14.5
cm to the right of the center of the panel.
Radar Positioning Measurements