Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
421
Troubleshoot the Switch
Chapter 9
Verify Boot Fast
Boot Fast failures are potentially fatal to the switch. Contact your Rockwell
Automation representative if your switch does not successfully complete Boot
Fast. You can disable Boot Fast and run a power-on self-test (POST) by using
the CLI.
Troubleshoot IP Addresses
The following table includes basic troubleshooting for issues that are related to
the switch IP address.
Troubleshoot
Device Manager
The following table includes basic troubleshooting for issues that are related to
Device Manager.
Issue
Resolution
IP address is not received from the DHCP server
If the switch does not receive an IP address from an upstream device operating as a DHCP server, make sure that the
device is operating as a DHCP server. Repeat Express Setup.
Switch has wrong IP address
If the switch is installed in your network but you cannot access the switch because it has the wrong IP address, assign a
new switch IP address.
Refer to Access Direct Managed Mode on page 423
to assign the IP address, and then update the
switch IP address on the Express Setup window.
Issue
Resolution
Device Manager does not appear
If you cannot display Device Manager from your computer, make sure that you entered the correct switch IP address in
the browser.
If you entered the correct switch IP address in the browser, make sure that the switch and your computer are in the
same network or subnetwork:
• For example, if your switch IP address is 172.20.20.85 and your computer address is 172.20.20.84, both devices are
in the same network.
• For example, if your switch IP address is 172.20.20.85 and your computer IP address is 10.0.0.2, the devices are in
different networks and cannot directly communicate without a router. You must either change the switch IP address
or change the computer IP address.
• If the issue persists, follow the procedure in
Access Direct Managed Mode on page 423
, and then update the switch
network settings on the Express Setup window.
• If the issue still persists, follow the procedure in the
Recover the Switch Firmware on page 426
Device Manager does not operate properly
Follow the procedure in
Access Direct Managed Mode on page 423
, and then update the switch network settings on the
Express Setup window.
If the issue persists, follow the procedure in
Recover the Switch Firmware on page 426
Device Manager is not accessible through the network
If you cannot access Device Manager remotely from a web browser, follow the procedure in the
Summary of Contents for ArmorStratix 5700 series
Page 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Page 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Page 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Page 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Page 547: ......