336
Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
Chapter 7
Configure Switch Features
Table 89 - Customize EIGRP Parameters
Field
Description
EIGRP ID
(Not editable). Displays the Autonomous System (AS) number of the EIGRP routing process.
Auto-Summary
Check the checkbox to allow the automatic summarization of subnet routes into network-level routes. This feature is disabled by default (the
software sends subprefix routing information across classful network boundaries). EIGRP summary routes are given an administrative distance
value of 5. You cannot configure this value.
Administrative Distance
Internal Distance
Type an administrative distance for EIGRP internal routes. Internal routes are routes that are learned from another entity within the same
autonomous system.
Valid values: 1…255
Default: 90
External Distance
Type an administrative distance for EIGRP external routes. External routes are routes for which the best path is learned from a neighbor external to
the autonomous system.
Valid values: 1…255
Default: 170
Metrics
Bandwidth
Type the minimum bandwidth of the route in kilobits per second.
Valid values: 1…4294967295
Loading
Type a number that represents the effective bandwidth of the route.
Valid values: 1…255 where 255 is 100 percent loading
Reliability
Type a number that represents likelihood of successful packet transmission.
Valid values: 0…255 where 255 means100 percent reliability; 0 means no reliability
Summary of Contents for ArmorStratix 5700 series
Page 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Page 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Page 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Page 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Page 547: ......