116
Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
Chapter 4
Install Stratix 5410 Switches
3. Insert the power supply module into the slot, and gently push it in.
When inserted correctly, the power-supply module is flush with the
switch.
4. Use a ratcheting torque screwdriver to torque each screw to 0.904…1.13
N•m (8…10 lb•in).
Wire the Power Source
To wire the power source, follow these steps.
1. Turn power off at the AC and DC circuits.
2. To loosen the captive screw on the power input terminal, use a Phillips
screwdriver.
PSU O
K
P
W
R
-RGD-
A
C
-DC
PSU
O
K
P
W
R
-R
GD
-A
C
-D
C
32557-M
IMPORTANT
If the power is not off at the AC or DC circuit breaker, do not touch
the power-input terminal.
32558-M
Console
28
ANA.TimeCode
Alarm
TOD
IN
OU