Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
Chapter 2
Get Started
Other status data
• Module identification (vendor ID, device type, product code, product name, revision, serial number)
• Major/minor fault status, I/O connection, module identity match
• Active alarms
• Major alarm relay (open, closed)
• Active faults
• Switch uptime since last restart
• Switch internal temperature in degrees Centigrade
• Management CPU utilization in percentage
• Power supply A present: yes, no
• Power supply B present: yes, no
• Number of active multicast groups
• IOS release version
• DLR ring status, members, and faults
• CIP connection counters: open/close requests, open/close rejects, timeouts
• Port alarm status per port: OK, Link Fault, Not Forwarding, Not Operating, High Bit Error Rate
• Port fault status per port: Error Disable, SFP Error, Native VLAN Mismatch, MAC address Flap Condition, Security Violation
• Port diagnostic counters per port: Ethernet interface counters (10), Ethernet media counters (12)
• Link status
• Traffic threshold exceeded per port: unicast, multicast, broadcast
• Cable diagnostics per port selected
• DHCP pool display: name, starting and ending IP address
• NAT: display name of instance, VLANs assigned per instance
• NAT diagnostics: active translations, total translated packets, blocked and pass-through traffic, ICMP and ARP fixups
Configuration data
• Major and minor revision of switch
• Electronic keying (Exact Match, Disable Keying)
• Connection (Input Data, Data)
• Data connection password
• Requested packet interval (RPI)
• Inhibit module
• Major fault on controller if connection fails while in Run mode
• Use unicast connections over EtherNet/IP
• Module fault display
• IP addressing method: Manual, DHCP
• IP address, subnet mask, primary and secondary DNS server address, default gateway (all if static)
• Host name
• Administration: contact name, geographic location
• Spanning Tree Mode (MST, RSTP, PVST+, RPVST+)
• Dual-power supply alarm enable
• Port configuration per port: enable/disable, auto-negotiate, speed, duplex
• Power over Ethernet (PoE): mode, status, power limit, power used, total power supported, total power used, remaining power
available
• Smartports and VLANs: assign roles per port, VLAN ID and name
• Port thresholds (incoming: unicast, multicast, broadcast, all outgoing traffic) rate limiting threshold per port: in packets per
second, bits per second, or percentage
• Port security: enable, allowed MAC IDs per port, dynamic, static
• DHCP pool: enable, delete, refresh, create
• DHCP address assignment per port
• Time sync configuration: enable per port, port state
• NAT configuration: create instance (private-to-public, public-to-private, traffic permits, and fixups)
Smartport assignment per port
• Role
• VLAN
Save and restore of switch configuration
Via File Obj
Table 12 - Data Accessible with CIP (Continued)
Data Type
Details
Summary of Contents for ArmorStratix 5700 series
Page 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Page 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Page 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Page 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Page 547: ......