210
Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
Chapter 7
Configure Switch Features
Figure 11 - Time Sync Information
Table 40 - Time Sync Information Fields
Field
Description
CIP Sync Time Synchronization
Displays whether the Precision Time Protocol is enabled or disabled on the device.
UTC System Time
Displays the current system time in units of microseconds.
Grandmaster Clock
Description
Displays information to identify the grandmaster clock, including the configured the clock type.
Identity
Displays the unique identifier for the grandmaster clock. The format depends on the network protocol.
Class
Displays a measure of the quality of the grandmaster clock. Values are defined from 0…255 with 0 as the best clock.
Accuracy
Indicates the expected absolute accuracy of the Grandmaster clock relative to CIP Sync time synchronization epoch (31 December, 1969
23:59:51.99918 UTC). The accuracy is specified as a graduated scale starting at 25 ns and ending at greater than 10 seconds or unknown.
For example, a GPS time source has an accuracy of approximately 250 ns. A hand-set clock typically has an accuracy less than 10 seconds. The
lower the accuracy value, the better the clock.
Variance
Displays the measure of inherent stability properties of the grandmaster clock. The value is in offset scaled log units. The lower the variance,
the better the clock.
Source
Displays the clock time source:
• Atomic Clock
• GPS
• Terrestrial Radio
• CIP Time Synchronization
• NTP
• HAND Set
• Other
• Internal Oscillator
Priority 1
Priority 2
Displays the relative priority of the grandmaster clock to other clocks in the system.
The value is between 0…255. The highest priority is 0.
Local Clock
Sync Status
Displays whether the local clock is synchronized or asynchronized with the grandmaster clock.
Offset to Master
Displays the offset value between the local clock and the master clock.
Identity
Displays the unique identifier for the local clock. The format depends on the network protocol.
• The Ethernet protocol encodes the MAC address into the identifier.
• The DeviceNet and ControlNet protocols encode the Vendor ID and serial number into the identifier.
Summary of Contents for ArmorStratix 5700 series
Page 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Page 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Page 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Page 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Page 547: ......