Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
147
Install Stratix 5700 Switches
Chapter 5
To insert an SFP module into an SFP slot, follow these steps.
1. Attach an ESD-preventive wriststrap to your wrist and to a grounded
bare metal surface.
2. Grasp both sides of the SFP module and align the module sideways in
front of the slot opening.
3. Insert the SFP module into the slot as shown in the following figure
until you feel the connector on the module snap into place in the rear of
the slot.
4. Remove the dust plugs from the SFP module optical ports, store them
for later use.
ATTENTION:
If the SFP module cannot be fully inserted, stop! Do not
force the module into the slot. Rotate the SFP module 180° and try
again.
IMPORTANT
Do not remove the dust plugs from the SFP module port or the
rubber caps from the fiber-optic cable until you are ready to connect
the cable.
The plugs and caps help protect the SFP module ports and cables
from contamination and ambient light.
SFP Module
(Bale-type Latch Shown)
32293-M