Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
381
Monitor the Switch
Chapter 8
Table 99 - Stratix 5410 System Status Indicators
Indicator
Status
Description
EIP Mod
The EIP Mod status indicator shows the status of the switch.
Off
Power to the switch is off or is not properly connected.
Solid green
The switch is operating properly.
Flashing green
The switch is not configured. For example, the switch does not have an IP address configured.
Flashing red
The switch has detected a recoverable system fault.
Solid red
The switch has detected a nonrecoverable system fault.
Flashing green and red
The switch is running its power-on self-test (POST).
EIP Net
The EIP Net status indicator shows the network status of the switch.
Off
Power to the switch is off or is not properly connected.
Solid green
The switch has an established CIP connection to one or more attached devices.
Flashing green
The switch has an IP address but the switch does not have an established connection to one or more attached devices.
Flashing red
One or more connections to attached devices have timed out.
Solid Red
The switch has detected that its IP address is already in use by another device in the network.
Flashing green and red
The switch is running its power-on self-test (POST).
Setup
The Setup status indicator shows the status of the initial setup of the switch.
Off
The switch is configured as a managed switch.
Solid green
The switch is in initial setup.
Flashing green
The switch is in initial setup, fault recovery, or initial setup is incomplete.
Solid amber
The switch failed to start initial setup or recovery because there is no available switch port to connect to the management station.
Disconnect a device from a switch port, then press the Express Setup button on the switch.
GPS
Not available in the current release.
TimeCD
Not available in the current release.
Alarms 1…4
The alarm input status indicators show the status of the alarm inputs.
Off
Alarm input is not configured.
Solid green
Alarm input is configured; no alarm detected.
Solid red
Minor alarm detected.
Flashing red
Major alarm detected.
Alternating green and
red
Critical alarm detected.
Alarm Out
The alarm input status indicator shows the status of the alarm output.
Off
Alarm Out is not configured.
Solid green
Alarm Out is configured; no alarm detected.
Solid red
Alarm detected.
PSU 1
PSU 2
The power status indicators show the status of power to the switch.
Off
Power is not present on the circuit, or the system is not powered up.
Solid green
Power output is good.
Flashing red
Power supply is installed, but power input is bad.
Solid red
Power output is bad.
Summary of Contents for ArmorStratix 5700 series
Page 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Page 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Page 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Page 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Page 547: ......