Configure Switch Features
Chapter 7
Configure SNMP via Device Manager
From the Configure menu, choose SNMP.
Community strings are passwords to the switch Management Information
Base (MIB). You can create community strings that provide a remote manager
read-only or read-write access to the switch.
To create, modify, and delete, click the Community Strings tab.
A read-only community string enables the switch to validate Get (read-only)
requests from a network management station. If you set the SNMP read
community, users can access MIB objects, but cannot change them.
A read-write community string enables the switch to validate Set (read-write)
requests from a network management station.