Accessories
E-3
IP67 Dynamic Brake Resistor
Note: Always check the resistor ohms against minimum resistance for drive being used.
Note: Duty Cycle listed is based on full speed to zero speed deceleration. For constance regen at full speed, duty cycle capability is half of what is listed. Application
Type 1 represents maximum capability up to 100% braking torque where possible. Application Type 2 represents more than 100% braking torque where possible, up
to a maximum of 150%.
Figure E.1 Dynamic Brake Resistor Approximate Dimensions
* Length is user-selectable based on the suffix added to the catalog number. For a length of 500±10mm, add
-M05
to the end of the catalog number. For a length of
100±10mm, add
-M1
to the end of the catalog number.
Application Type 1
Application Type 2
Drive and
Motor Size
kW
Part Number
Resistance
Ohms ± 5%
Continuous
Power kW
Max Energy
kJ
Max Braking
Torque % of
Motor
Braking
Torque % of
Motor
Duty
Cycle %
Braking
Torque % of
Motor
Duty
Cycle %
400-480 Volt AC Input Drives
0.37 (0.5)
284R-360P500
360
0.086
17
305%
100%
47%
150%
31%
0.75 (1)
284R-360P500
360
0.086
17
220%
100%
23%
150%
15%
1.5 (2)
284R-360P500
360
0.086
17
110%
100%
12%
110%
11%
2.2 (3)
284R-120P1K2
120
0.26
52
197%
100%
24%
150%
16%
4 (5)
284R-120P1K2
120
0.26
52
124%
100%
13%
124%
10%
Cat No.
A
mm (in.)
B
mm (in.)
C
D
mm (in.)
E
mm (in.)
F
mm (in.)
G
mm (in.)
H
mm (in.)
J
mm (in.)
284R-091P500
75 ± 3
(2.95 ± 0.12)
215 ± 5
(8.46 ± 0.2)
*
235 ± 5
(9.25 ± 0.2)
60 ± 2
(2.36 ± 0.08)
127
(5)
12.54
(0.49)
60 ± 2
(2.36 ± 0.08)
50 ± 1.5
(1.97 ± 0.06)
284R-360P500
284R120P1K2
420 ± 5
(16.54 ± 0.2)
440 ± 5
(17.32 ± 0.2)
H
J
F
C
G
B
D
E
A
Summary of Contents for ArmorStart Bulletin 280G
Page 1: ...USER MANUAL Bulletin 280G 281G 284G ArmorStart Distributed Motor Controller ...
Page 2: ......
Page 18: ...1 8 Product Overview Notes ...
Page 29: ...Installation and Wiring 2 11 Figure 2 8 Bulletin 1000 ArmorStart ...
Page 30: ...2 12 Installation and Wiring Figure 2 9 Bulletin 1000 ArmorStart ...
Page 42: ...2 24 Installation and Wiring Figure 2 20 Bulletin 1000 Safety ArmorStart ...
Page 43: ...Installation and Wiring 2 25 Figure 2 21 Bulletin 1000 ArmorStart ...
Page 54: ...2 36 Installation and Wiring Notes ...
Page 80: ...3 26 Bulletin 280G 281G Programmable Parameters Notes ...
Page 157: ...Explicit Messaging on DeviceNet 6 7 ...
Page 161: ...Explicit Messaging on DeviceNet 6 11 Figure 6 5 ControlLogix Example of Ladder Logic Program ...
Page 162: ...6 12 Explicit Messaging on DeviceNet Notes ...
Page 209: ...Troubleshooting 10 21 Figure 10 7 Control Voltage Fuse Replacement Control Voltage Fuse ...
Page 210: ...10 22 Troubleshooting Notes ...
Page 224: ...A 14 Specifications Notes ...
Page 250: ...B 26 Bulletin 280G 281G CIP Information Notes ...
Page 292: ...E 4 Accessories Notes ...
Page 300: ...F 8 Safety I O Module and TÜV Requirements Notes ...
Page 321: ...Step Logic Basic Logic and Timer Counter Functions I 7 Notes ...
Page 322: ...I 8 Step Logic Basic Logic and Timer Counter Functions Notes ...
Page 323: ......