Specifications
A-11
ArmorConnect™ Three-Phase Power Media
Table 1.A Patchcords
➊
The cat. no. is incomplete as shown. For desired length, replace the symbol with: 05 —0.5 m (1.62 ft), 1—1 m (3.3 ft), 015—1.5 m (4.9 ft), 2—2 m (6.5 ft),
025—2.5 m (8.1 ft), 3—3 m (9.8 ft), 4—4 m (13.1 ft), 6—6 m (19.7 ft), 8—8 m (26.2 ft), 10—10 m (32.8 ft), 12—12 m (39.4 ft), or 14—14 m (45.9 ft).
Specifications
Pinout and Color Code
Approximate Dimensions
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes and are subject to change.
Pin
Count
Assembly
Rating
Cat. No.
0
0
4-pin
600V, 25 A
Straight Female
Straight Male
Right-Angle Female
Straight Male
Straight Female
Right-Angle Male
Right-Angle Female
Right-Angle Male
280-PWRM35A-M
➊
280-PWRM35A-M
➊
280-PWRM35A-M
➊
280-PWRM35A-M
➊
Mechanical
Coupling Nut
Black Anodized Aluminum or 316 Stainless Steel
Housing
Black PVC
Insert
Black PVC
Cable Diameter
0.775 in. +/- 0.12 in. (19.68 mm +/- 0.5 mm)
Electrical
Contacts
Copper Alloy with Gold over Nickel Plating
Cable
Black PVC, dual rated UL TC/Open Wiring and STOOW
Cable Rating
600V AC/DC
Assembly Rating
600V @ 25 A, Symmetrical Amps RMS Fault: 65 kA when
used with Class CC, T, or J type fuses
or 100 A circuit breaker
Environmental
Enclosure Type Rating
IP67, NEMA 4; IP69K 1200 psi washdown
Operating Temperature
UL Type TC 600V 90 °C Dry 75 °C Wet, Exposed Run (ER) or
MTW 600V 90 °C or STOOW 105 °C 600V -
CSA STOOW 600V FT2
Certifications
UL Listed (File No. E318496, Guide PVVA)
Standards Compliance
UL 2237
Face View Pinout
4-pin
Female
Male
Color Code
1 Black
3 Red
2 Green/Yellow Extended PIN
4 White
88.9 (3.50)
38.6
(1.52)
Female straight
(1.95 - 2.25)
(2.94)
(1.52)
74.7
49.5 - 57.1
38.6
Female 90 deg.
88.9 (3.50)
38.6
(1.52)
Male straight
(1.95 - 2.25)
(2.94)
(1.52)
74.7
49.5 - 57.1
38.6
Male 90 deg.
Example of a Patchcord
Summary of Contents for ArmorStart Bulletin 280G
Page 1: ...USER MANUAL Bulletin 280G 281G 284G ArmorStart Distributed Motor Controller ...
Page 2: ......
Page 18: ...1 8 Product Overview Notes ...
Page 29: ...Installation and Wiring 2 11 Figure 2 8 Bulletin 1000 ArmorStart ...
Page 30: ...2 12 Installation and Wiring Figure 2 9 Bulletin 1000 ArmorStart ...
Page 42: ...2 24 Installation and Wiring Figure 2 20 Bulletin 1000 Safety ArmorStart ...
Page 43: ...Installation and Wiring 2 25 Figure 2 21 Bulletin 1000 ArmorStart ...
Page 54: ...2 36 Installation and Wiring Notes ...
Page 80: ...3 26 Bulletin 280G 281G Programmable Parameters Notes ...
Page 157: ...Explicit Messaging on DeviceNet 6 7 ...
Page 161: ...Explicit Messaging on DeviceNet 6 11 Figure 6 5 ControlLogix Example of Ladder Logic Program ...
Page 162: ...6 12 Explicit Messaging on DeviceNet Notes ...
Page 209: ...Troubleshooting 10 21 Figure 10 7 Control Voltage Fuse Replacement Control Voltage Fuse ...
Page 210: ...10 22 Troubleshooting Notes ...
Page 224: ...A 14 Specifications Notes ...
Page 250: ...B 26 Bulletin 280G 281G CIP Information Notes ...
Page 292: ...E 4 Accessories Notes ...
Page 300: ...F 8 Safety I O Module and TÜV Requirements Notes ...
Page 321: ...Step Logic Basic Logic and Timer Counter Functions I 7 Notes ...
Page 322: ...I 8 Step Logic Basic Logic and Timer Counter Functions Notes ...
Page 323: ......