3-16
Bulletin 280G/281G Programmable Parameters
ZIP Parameters
Starter Option
Bit 0 = HOA Keypad
Bit 1 = Safety Monitor
Bit 2 = Source Brake
Bits 4-15 = Reserved
Parameter Number
60
Access Rule
GET
Data Type
WORD
Group
Misc.
Units
—
MinimumValue
0
Maximum Value
66535
Default Value
—
AutoRun Zip
Enables ZIP data production on
power up
0=Disable
1=Enable
Parameter Number
67
Access Rule
Get/Set
Data Type
BOOL
Group
ZIP Parameters
Units
MinimumValue
0
Maximum Value
1
Default Value
0
Zone Produced EPR
The Expected Packet Rate in
msec. Defines the rate at which
ZIP data is produced. Defaults to
75 msec.
Parameter Number
68
Access Rule
GET/SET
Data Type
UINT
Group
Zip Parameter
Units
msec
MinimumValue
0
Maximum Value
65535
Default Value
75
Zone Produced PIT
The Production Inhibit Time in
msec. Defines the minimum time
between Change of State data
production
Parameter Number
69
Access Rule
GET/SET
Data Type
UINT
Group
ZIP Parameters
Units
msec
MinimumValue
0
Maximum Value
65535
Default Value
75
Zone #1 MAC ID
The node address of the device
whose data is to be consumed
for zone 1
Parameter Number
70
Access Rule
GET/SET
Data Type
USINT
Group
ZIP Parameters
Units
—
MinimumValue
0
Maximum Value
64
Default Value
64
Summary of Contents for ArmorStart Bulletin 280G
Page 1: ...USER MANUAL Bulletin 280G 281G 284G ArmorStart Distributed Motor Controller ...
Page 2: ......
Page 18: ...1 8 Product Overview Notes ...
Page 29: ...Installation and Wiring 2 11 Figure 2 8 Bulletin 1000 ArmorStart ...
Page 30: ...2 12 Installation and Wiring Figure 2 9 Bulletin 1000 ArmorStart ...
Page 42: ...2 24 Installation and Wiring Figure 2 20 Bulletin 1000 Safety ArmorStart ...
Page 43: ...Installation and Wiring 2 25 Figure 2 21 Bulletin 1000 ArmorStart ...
Page 54: ...2 36 Installation and Wiring Notes ...
Page 80: ...3 26 Bulletin 280G 281G Programmable Parameters Notes ...
Page 157: ...Explicit Messaging on DeviceNet 6 7 ...
Page 161: ...Explicit Messaging on DeviceNet 6 11 Figure 6 5 ControlLogix Example of Ladder Logic Program ...
Page 162: ...6 12 Explicit Messaging on DeviceNet Notes ...
Page 209: ...Troubleshooting 10 21 Figure 10 7 Control Voltage Fuse Replacement Control Voltage Fuse ...
Page 210: ...10 22 Troubleshooting Notes ...
Page 224: ...A 14 Specifications Notes ...
Page 250: ...B 26 Bulletin 280G 281G CIP Information Notes ...
Page 292: ...E 4 Accessories Notes ...
Page 300: ...F 8 Safety I O Module and TÜV Requirements Notes ...
Page 321: ...Step Logic Basic Logic and Timer Counter Functions I 7 Notes ...
Page 322: ...I 8 Step Logic Basic Logic and Timer Counter Functions Notes ...
Page 323: ......