A-2
Specifications
Bulletin 280G/281G, Continued
Electrical Ratings
UL/NEMA
IEC
Environmental
Operating Temperature Range
-20…40°C (-4…104°F)
Storage and Transportation
temperature range
–25….85°C (–13…185°F)
Altitude
2000 m
Humidity
5…95% (non-condensing)
Pollution Degree
3
Enclosure Ratings
NEMA 4/12/13
IP67
Approximate Shipping Weight
6.8 kg (15 lbs.)
Mechanical Resistance to Shock
Operational 15
G
Non-Operational 30
G
Resistance to Vibration
Operational
1 G, 0.15 mm (0.006 in.) displacement
Non-Operational
2.5 G, 0.38 mm (0.015 in.) displacement
Power and Ground Terminals
WireSize
Primary/Secondary Terminal:
#16 AWG…#10 AWG
Primary/Secondary Terminal:
1.5 mm
2
…4.0 mm
2
Tightening Torque
Primary Terminal: 10.8 in·lb
Secondary Terminal: 4.5 in·lb
Primary Terminal: 1.2 N·m
Secondary Terminal: 0.5 N·m
Wire Strip Length
0.35 in. (9 mm)
Control and Safety Monitor Inputs
WireSize
#18 AWG…#10 AWG
1.0 mm
2
…4.0 mm
2
Tightening Torque
6.2 in·lb
0.7 N·m
Wire Strip Length
0.35 in. (9 mm)
Other Rating
EMC Emission levels
Conducted Radio Frequency Emissions
Class A
Radiated Emissions
Class A
EMC immunity levels
Electrostatic Discharge
4 kV contact and 8 kV Air
Radio Frequency Electromagnetic Field
10 V/m
Fast Transient
2 kV
Surge Transient
1 kV L-L, 2 kV L-N (Earth)
Overload Characteristics
Overload Current Range
0.5…2.5 A
1.1…5.5 A
3.2…16 A
Trip Classes
10, 15, 20
Trip Rating
120% of FLC setting
Number of poles
3
DeviceNet Specifications
DeviceNet Supply Voltage Rating
Range 11…25V DC, 24V DC Nominal
DeviceNet Input Current
167 mA @ 24V DC - 4.0 W
364 mA @ 11V DC - 4.0 W
External Devices powered by DeviceNet
Sensors Inputs 6* 50 mA - total 300 mA
Total w/max. Sensor Inputs (6)
367 mA @ 24V DC - 8.8 W
DeviceNet Input Current Surge
15 A for 250 μs
DeviceNet Communications
Baud Rates
125, 250, 500 kbps
Distance Maximum
500 m (1630 ft) @ 125 kbps
200 m (656 ft) @ 250 kbps
100 m (328 ft) @ 500 kbps
Motor Cable
10 AWG for all motor sizes
Certifications
cULus (File No. E3125)
UL 508
EN/IEC 60947-4-1
CE Marked per Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC
Summary of Contents for ArmorStart Bulletin 280G
Page 1: ...USER MANUAL Bulletin 280G 281G 284G ArmorStart Distributed Motor Controller ...
Page 2: ......
Page 18: ...1 8 Product Overview Notes ...
Page 29: ...Installation and Wiring 2 11 Figure 2 8 Bulletin 1000 ArmorStart ...
Page 30: ...2 12 Installation and Wiring Figure 2 9 Bulletin 1000 ArmorStart ...
Page 42: ...2 24 Installation and Wiring Figure 2 20 Bulletin 1000 Safety ArmorStart ...
Page 43: ...Installation and Wiring 2 25 Figure 2 21 Bulletin 1000 ArmorStart ...
Page 54: ...2 36 Installation and Wiring Notes ...
Page 80: ...3 26 Bulletin 280G 281G Programmable Parameters Notes ...
Page 157: ...Explicit Messaging on DeviceNet 6 7 ...
Page 161: ...Explicit Messaging on DeviceNet 6 11 Figure 6 5 ControlLogix Example of Ladder Logic Program ...
Page 162: ...6 12 Explicit Messaging on DeviceNet Notes ...
Page 209: ...Troubleshooting 10 21 Figure 10 7 Control Voltage Fuse Replacement Control Voltage Fuse ...
Page 210: ...10 22 Troubleshooting Notes ...
Page 224: ...A 14 Specifications Notes ...
Page 250: ...B 26 Bulletin 280G 281G CIP Information Notes ...
Page 292: ...E 4 Accessories Notes ...
Page 300: ...F 8 Safety I O Module and TÜV Requirements Notes ...
Page 321: ...Step Logic Basic Logic and Timer Counter Functions I 7 Notes ...
Page 322: ...I 8 Step Logic Basic Logic and Timer Counter Functions Notes ...
Page 323: ......