
【
Start Setup
】
【
Exit Setup
】
75
Plessey
Restore the Default Value
By reading the barcode, the parameter setup of Plessey will be restored to the factory default state.
Restore the Default Setup Value of Plessey
Allow to Read Plessey or not
Allow to Read Plessey
Prohibit Reading Plessey
Note: the scanner will become unable to read Plessey by reading the setup barcode “Prohibit Reading Plessey”, thus, if
the scanner is unable to read the Plessey, please try to read the setuo barcode “allow to read Plessey”.
CodeID Setup
To activate the
setup function by reading “CodeID setup”, then read the hexadcimal value inaccordance with the character
which will be set to the CodeID.
Code ID Setup
Example: Set the CodeID ofPlessey
to “p” (the hexadcimal value is 0x70).
1.
Read the “Start Setup” barcode.
2.
Read the “CodeID Setup” barcode.
3.
Read the numeric barcode “7”, “0” (see the appendix—numeric barcode)
4.
Read the “Save” barcode.(see the appendix—numeric barcode)
5.
Read the “Exit Setup” barcode.
Check Setup
Plessey barcode data does not compulsively include the check digit, if check digit exists, then it is the last character.
Check digit is calculated according to all the datas, for checking if the data is correct or not.
Set “No Check”, the scanner will transmit all the barcode data
Set “Check but do not Send Check digit”, the scanner will check according to the last bit, if successful, all the data
except for the check digit will be transmitted, if failed, then the scanner will indicate “barcode reading failed”
Summary of Contents for RS 1100
Page 1: ...Robin RS 1100 Scanner User Guide...
Page 9: ...Save and Abort the Setup 94...
Page 10: ......
Page 18: ...8 Reading Depth of Field...
Page 25: ...Start Setup Exit Setup 15 SetupProcess Flow...
Page 37: ...Start Setup Exit Setup 27 USB Virtual Serial Port Function USB Virtual Serial Port Function...