Start Setup
】
68
【
Exit Setup
】
Restore the Default Setup Value of Codabar
Allow to Read Codabar or not
Allow to Read Codabar
Prohibit Reading Codabar
Note: the scanner will become unable to read Codabar by reading the setup barcode “Prohibit Reading Codabar”, thus, if
the scanner is unable to read
theCodabar, please try to read the setuo barcode “allow to read Codabar”.
CodeID Setup
To activate the setup function by reading “CodeID setup”, then read the hexadcimal value inaccordance with the character
which will be set to the CodeID.
Code ID Setup
Example: Set the CodeID ofCodabar
to “p” (the hexadcimal value is 0x70).
1.
Read the “Start Setup” barcode.
2.
Read the “CodeID Setup” barcode.
3.
Read the numeric barcode “7”, “0” (see the appendix—numeric barcode)
4.
Read the “Save” barcode.(see the appendix—numeric barcode)
5.
Read the “Exit Setup” barcode.
Check Setup
Codabar barcode data does not compulsively include the check digit, if check digit exists, then it is the last character.
Check digit is calculated according to all the datas, for checking if the data is correct or not.
Set “No Check”, the scanner will transmit all the barcode data
Set “Check but do not Send Check digit”, the scanner will check according to the last bit, if successful, all the data
except for the check digit will be
transmitted, if failed, then the scanner will indicate “barcode reading failed”
Set “Check and Send Check digit” the scanner will check according to the last bit, if successful, all the data including
the check digit will be transmitted, the check digit will be treated as the last bit of the normal data; if failed, then the
scanner will indicate “barcode reading failed”