Transmitter controls
F X - 4 0
7
In the Linkage menu
“Dial Monitor”
the current and stored
positions of the rotary knobs are displayed in bar graph form.
The centre rotary knob CD is a digital control with no end-
stops, and it also features an integral push-button function
(CD-SW). This control can also be assigned freely to any func-
tion. The transmitter emits an audible signal when the knob is
moved to the centre position. The position of this control is
also displayed on the Start screen.
•
LINEAR SLIDERS
The centre of the transmitter houses three linear sliders with a
centre detent. These analogue controls can also be assigned
freely to any function you wish. The transmitter emits an audi-
ble signal when the slider is moved to the centre position.
In the Linkage menu
“Dial Monitor”
the current and stored
positions of the linear sliders are displayed in bar graph form.
•
DIGITAL TRIMMERS
The transmitter features two digital trimmer buttons (T5 + T6).
Every time a button is moved, the trimmer value alters by the
selected increment. If a trimmer button is held at one end-
point in order to adjust the trimmer value by a larger amount,
the rate of change automatically accelerates (auto-repeat
function).
If the trimmer position reaches the neutral point (centre posi-
tion), or passes the neutral point, the transmitter emits an
audible signal. The current trim position is displayed as a bar
graph in the Start display and also in the
“Dial Monitor”
menu.
The trimmer buttons can be assigned freely to any functions,
and can also be used as transmitter controls for mixer func-
tions.
The trimmer rate and increment can be selected individually
for each trim button in the
“Function”
menu.
• You can fit the switches in any position you like.
The default position of the switches is as follows:
In each case the centre wire of the cable is colour-coded, and
is assigned permanently to the following switches:
Please ensure that the wire
colours are correctly connec-
ted after you have re-positio-
ned the switches, otherwise
the graphical on-screen
assignment will be displayed
incorrectly.
•
After re-positioning the switches, fit the crown nuts again
and tighten them using the special spanner supplied.
•
Fit the back panel and tighten the retaining screws.
After the re-positioning exercise you should now call up the
System menu “Switch” (page 35) and alter the switch types
and position numbers, so that the graphical switch position di
play reflects the new configuration and is displayed correctly on
the screen.
•
CENTRAL ROTARY KNOBS
The rotary knobs LD and RD are analogue controls which can
be assigned freely to any function. They feature a fine centre
detent, and the transmitter emits an audible signal when they
are moved to the centre position. If you wish, they can be
retracted by pushing the knob in using light pressure.
Switch
Position
Typ
Lever
SA
3-position Change-over
Short
SB
3-position Change-over
Short
SC
3-position Change-over
Long
SD
3-position Change-over
Short
SE
3-position Change-over
Short
SF
2-position Change-over
Long
SG
3-position Change-over
Short
SH
3-position Change-over
Short
SWITCH
Cable colour
SA and SC
green
SB and SD
yellow
SE and SG
orange
SF and SH
brown
L1
L2
L3