7. COMMUNICATION DATA LIST
IMR01Y36-E2
58
Continued from the previous page.
ID
Name
Number
of data
items
Attri-
bute
Data range
Factory
set value
86
(0x0056)
Input scale high
64
R/W TC/RTD inputs:
Input scale low to Maximum value of
the selected input range
Voltage (V)/Current (I) inputs:
−
19999 to +19999
(However, a span is 20000 or less.)
Varies with the setting of the Decimal
point position
TC/RTD:
Maximum
value of the
selected input
range
V/I: 100.0
87
(0x0057)
Input scale low
64
R/W TC/RTD inputs:
Minimum value of the selected input
range to Input scale high
Voltage (V)/Current (I) inputs:
−
19999 to +19999
(However, a span is 20000 or less.)
Varies with the setting of the Decimal
point position
TC/RTD:
Minimum value
of the selected
input range
V/I: 0.0
88
(0x0058)
Input error determination
point (high)
64 R/W Input error determination point (low) to
(Input range high + 5 % of input span)
Input scale high
+ (5 % of input
span)
89
(0x0059)
Input error determination
point (low)
64 R/W (Input range low
−
5 % of input span) to
Input error determination point (high)
Input scale low
−
(5 % of input
span)
90
(0x005A)
Burnout direction
64
R/W 0: Upscale
1: Downscale
Validate only when the TC input and
Voltage (low) input are selected.
0
91
(0x005B)
Square root extraction
64
R/W 0: Unused
1: Used
0
92
(0x005C)
Unused
⎯
⎯
⎯
⎯
•
•
•
95
(0x005F)
96
(0x0060)
Output assignment
(Logic output selection
function)
64 R/W 0: Control output
1: Logic output result
2: FAIL output
0
97
(0x0061)
Unused
⎯
⎯
⎯
⎯
•
•
•
100
(0x0064)
101
(0x0065)
Energized/De-energized
(Logic output selection
function)
64 R/W 0: Energized
1: De-energized
0
102
(0x0066)
Unused
⎯
⎯
⎯
⎯
•
•
•
113
(0x0071)
Continued on the next page.