APPENDIX
IMR01Y36-E2
114
Continued from the previous page.
ID
Description
Get
Set
Type
Value
Attributes
208 ST start condition
Yes
Yes
INT
Refer to P. 70
209 Automatic temperature rise group
Yes
Yes
INT
Refer to P. 70
210 Automatic temperature rise learning
Yes
Yes
INT
Refer to P. 70
211 Automatic temperature rise dead time
Yes
Yes
INT
Refer to P. 71
212 Automatic temperature rise gradient data
Yes
Yes
INT
Refer to P. 71
213
Unused
No
No
UINT
⎯
214 Setting change rate limiter unit time
Yes
Yes
INT
Refer to P. 71
215 Soak time unit
Yes
Yes
INT
Refer to P. 71
216 Setting limiter high
Yes
Yes
INT
Refer to P. 71
217 Setting limiter low
Yes
Yes
INT
Refer to P. 71
218 PV transfer function
Yes
Yes
INT
Refer to P. 71
219
Unused
No
No
UINT
⎯
220
Unused
No
No
UINT
⎯
221
Unused
No
No
UINT
⎯
222
Unused
No
No
UINT
⎯
223
Unused
No
No
UINT
⎯
224
Unused
No
No
INT
⎯
225 Controller state 1
Yes
No
WORD
Refer to P. 71
226 Controller state 2
Yes
No
WORD
Refer to P. 72
227
Unused
1
No
No
UINT
⎯
228
Unused
1
No
No
UINT
⎯
229
Unused
1
No
No
UINT
⎯
230
Unused
1
No
No
UINT
⎯
231 Comprehensive alarm state
2, 3
Yes
No
WORD
Refer to P. 72
232 Controller alarm state
2, 4
Yes
No
WORD
Refer to P. 72
233
Error
state
2, 4
Yes
No
WORD
Refer to P. 72
234
RUN/STOP
2, 4
Yes
Yes
WORD
Refer to P. 73
235 Setting change flag
2, 3
Yes
No
WORD
Refer to P. 73
236 Number of Polling I/O
communication controllers
2, 3, 5
Yes
Yes
UNIT
Refer to P. 73
237
Unused
No
No
UINT
⎯
238 COM-JH error code
2, 3, 6
Yes
No
WORD
Refer to P. 73
1
If this data item is set as a measured data item (IN) or setting data item (OUT) by the “Controller
communication item setting object (0xC7: C7Hex)” which sets communication data items via Polling
I/O communication, it becomes the same as that when set at “0.” In addition, any data item set hereafter
is invalidated.
2
It is validated only via Explicit message communication. If this data item is set as a measured data item
(IN) or setting data item (OUT) by the “Controller communication item setting object (0xC7: C7Hex)”
which sets communication data items via Polling I/O communication, it becomes the same as that when
set at “0.” In addition, any data item set hereafter is invalidated.
3
Only object instances 1 is validated.
4
Only object instances 1 and 2 are validated.
5
Data for the set number of controllers is assigned by Polling I/O communication. The number of
assigned data items is the number of data items for the set number of modules in each item of the
attributes set in “Controller communication item setting object (0xC7: C7Hex).”
6
Causes of controller communication errors
−
No controllers are connected.
−
“0” is set for all controller addresses.
−
The controller timed out after recognition.
−
An abnormal condition exists in communication.
Continued on the next page.