![Rinstrum AxleweighR R420 Reference Manual Download Page 136](http://html1.mh-extra.com/html/rinstrum/axleweighr-r420/axleweighr-r420_reference-manual_1463210136.webp)
Reference Manual Rev 1.13
Page 136
004R-646-113
Error
Description
Resolution
(ERROR)
(ILOCK)
(K422 only) The interlock went low during
an axle capture or the interlock time was
exceeded.
(ERROR)
(Exxxx)
(K422 only) Axle weighing will be aborted
if an application error occurs during the
truck.
(ERROR)
(O.LOAD)
(K422 only) Axle weighing will be aborted
if the scale is overloaded during the truck.
(ERROR)
(U.LOAD)
(K422 only) Axle weighing will be aborted
if the scale is underloaded during the
truck
Table 18: Errors: axle weighing
22.4. Setup Errors
These messages show status messages or errors that may occur during the
instrument setup. See section 13.4 for calibration errors.
Error
Description
Resolution
(ENTRY)
(DENIED)
When accessing setup, more
than three attempts have
been made with the incorrect
passcode.
Turn the instrument off. When
the instrument is turned back
on, enter the correct passcode
to access setup.
(WR DENIED)
(RD DENIED)
The instrument may be in
Safe Setup and an item that
needs Full Setup has been
selected for editing.
Access Full Setup to access this
item.
Table 19: Errors: setup
22.5. Diagnostic Errors
The instrument continually monitors the condition of the internal circuits. Any faults
or out-of-tolerance conditions are shown on the display as an
E
type error message.
In the table below the following terms are used:
Check
: This item can be checked on site by service personnel.
Return for Service
: The instrument must be returned for factory service.
Error
Description
Resolution
(E0001) The power supply voltage is too low.
Check supply
(E0002) The power supply voltage is too high.
Check scale / cables
(E0004) Positive sense voltage out or range.
Check scale connections
and SCALE:BUILD:CABLE
setting.
(E0008) Negative sense voltage out or range.
Check scale connections
and SCALE:BUILD:CABLE
setting.
(E0010) Temperature is outside of allowable limits Check location
(E0020) Module Error
Replace Module
(E0200) The calibration information has been lost. Re-calibrate
(E0400) The factory information has been lost.
Return for Service