004R-646-113
AND (LGC.AND)
: Setpoint is active when all inputs in the mask are on.
OR (LGC.OR)
: Setpoint is active when any inputs in the mask are on.
XOR (LGC.XOR)
: Setpoint is active when only one input in the mask is on.
SOURCE:
Select the source for the setpoint to use.
Options are:
IO
use the external IO
Status
use the instrument status
SETP
use the setpoint status
REG
use a register value
REG:
If the source is set to register (REG) then this setting is used to set the
register to use. The register must be a number or weight value. The decimal value
of the register address should be used.
MASK
: A 32 bit number that is use to match against the selected source. If the
source is set to IO then IO1 is the least significant (first) bit and IO32 is the most
significant (32
nd
) bit. If the source is set to setpoint (SETP) then setpoint 1 is the
least significant (first) bit and setpoint 8 is the eighth bit as shown in the second
table below. The instrument status is broken down in the following table. This
number should be entered as a decimal value.