Chapter 3 Arbitrary Waveform Output
DG4000 User's Guide
3-16
Example: Edit Block
The following example introduces how to use "Edit Block" to create an arbitrary
waveform fulfilling the following conditions.
Parameter
Value
Cycle Period
12μs
HiLevel
4V
LoLevel
-2V
Interp
Linear
X1Y1
2, 4V
X2Y2
4, -2V
Operation Procedures:
1.
Press
Arb and use
to open the 2/2 menu page; then press
Create New
Cycle Period, use the numeric keyboard to input "12" and select the unit
"μsec" from the pop-up menu.
2.
Press
HiLevel, use the numeric keyboard to input "4" and select the unit "V"
from the pop-up menu.
3.
Press
LoLevel, use the numeric keyboard to input "-2" and select the unit "V"
from the pop-up menu.
4.
Press
Points, use the numeric keyboard to input "4" and press OK. Note: At
this point, a -2 V level line is displayed.
5.
Press
Interp to select "Linear".
6.
Press
Edit Block
to enter the "Edit Block" interface.
1)
Press
X1, use the numeric keyboard to input "2" and press OK. Then,
press
Y1, use the numeric keyboard to input "4" and select the unit "V"
from the pop-up menu. Use the same method to set X2 and Y2.