Burst Delay
Burst delay is only available for N cycle and infinite burst mode. It is defined as the
time from when the generator receives the trigger signal to starts to output the N
Cycle (or Infinite) burst.
When
Burst is enabled, press Type
"N Cycle" or "Infinite"; then, press
to
open the 2/2 menu page and press
Delay. Use the numeric keyboard or the
direction keys and knob to input the desired delay. The delay should be no less than
0s and no greater than 85s. The default is 0s.
Burst Trigger Source
Burst trigger source could be internal, external or manual. The generator will
generate a burst output when a trigger signal is received and then wait for the next
trigger.
When
Burst is enabled, press Source to select "Int", "Ext" or "Manual". The
default setting is "Int".
1.
Internal Trigger
When internal trigger is selected, the generator can only output N cycle burst
and the burst frequency is determined by the "Burst Period".
2.
External Trigger
When external trigger is selected, the generator can output N cycle, infinite or
gated burst. The generator receives the trigger signal from the
[Mod/FSK/Trig] connector at the rear panel. A burst will be generated once
the connector receives a TTL pulse with specified polarity. To set the TTL pulse
polarity, press
SlopeIn to select "Leading" or "Trailing" and the default
setting is "Leading".
Note: In "Int" trigger and "Manual" trigger, the corresponding menu is
TrigOut. The [Mod/FSK/Trig] connector at the rear panel is used as the